 WARNING

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN 

RESULT IN DEATH OR SERIOUS INJURY 

•  When working with electrical equipment or lead acid batteries, have someone nearby in case of an 

emergency.

• 

servicing the battery connected to the charger. 

•  Wear eye protection and gloves.
•  Avoid touching your eyes while using this unit.
•  Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If this occurs, 

cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention.

• 
•  Never attempt to re-charge a damaged, frozen or non-rechargeable battery.
•  Keep unit away from moist or damp areas.
•  Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit 

which goes through the battery or another electrical tool that may create an explosion.

•  Battery charger must be plugged in to an earthed and Australian Standards compliant mains supply. 

If the units power cable is damaged, replace the cable immediately. 

 LIMITATIONS OF USE

•  Do not use in connection with life support systems or other medical equipment or devices. 
•  Charger is not to be used by persons with reduced physical or mental capabilities or lack of knowledge 

and experience. Not to be operated or used by children.

Enerdrive ePOWER Industrial Battery Charger Owner’s Manual (Rev. 1.4)

Page 6

Summary of Contents for ePower Industrial EPI-2430

Page 1: ...Operation Owner s Manual 24V 36V 48V Models Rev 1 4...

Page 2: ......

Page 3: ...may result in damage to the unit batteries and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for future reference Product Numbers ePOWER Industrial...

Page 4: ...o responsibility or liability for losses damages costs or expenses whether special direct indirect consequential or incidental which might arise out of the use of such information The use of any such...

Page 5: ...E INSTRUCTIONS CONNECTIONS CABLE CONNECTIONS 8 9 5 FAULT INDICATOR 12 6 WATERPROOFING INSTALLATION 13 7 SPECIFICATIONS 14 8 CHARGE PROFILE 15 CHARGE PROFILE INSTRUCTIONS 15 CHARGE PROFILE TABLE 16 9 W...

Page 6: ...gs on or provided with the battery charger and all appropriate sections of this guide The Enerdrive ePOWER Industrial Battery Charger contains no user serviceable parts Opening up the charger will voi...

Page 7: ...non rechargeable battery Keep unit away from moist or damp areas Avoid dropping any metal tool or object on the battery Doing so could create a spark or short circuit which goes through the battery o...

Page 8: ...nlight heat moisture or conductive contaminants Do not install the ePOWER Industrial Battery Charger in corrosive environments When placing the unit allow a minimum of 75mm of space around the unit fo...

Page 9: ...er to oil dirt mud or direct heavy water spray when cleaning vehicle 2 The enclosure of the charger has been tested successfully to EN60529 meeting IP66 compliance 3 If the detachable AC input power s...

Page 10: ...s to EPI 2430 EPI 3620 EPI 4815 EPI 4835 to December 2018 Interlock Connection the interlock circuit is a normally closed contact and when AC is applied to the charger this contact will switch to an o...

Page 11: ...normally open or normally closed circuit with no voltage which change state when the charger is operational Normally open Normally closed Common Image refers to EPI 2430 EPI 3620 EPI 4815 EPI 4835 fro...

Page 12: ...DC Battery Connection Brake Switch Red Positive Black Negative White Temp Sens When AC has power open circuit When AC has NO power closed circuit Charger Switch Remote LED Open circuit charger ON Clos...

Page 13: ...Protection 1 Charger shuts down and enters protection mode due to charger environmental temperature is too high Please place the charger in a well ventilated environment 2 Disconnect the charger and...

Page 14: ...PROOFING INSTALLATION Waterproof ring installation of the AC input cable 1 Slip waterproof ring or grommet over the AC input cable 2 correctly 3 NOTE Take care to not overtighten the waterproof clamp...

Page 15: ...W Dimensions Weight OperatingTemperature StorageTemperature AGM Flooded GEL Lithium Electronic Protection auto reset Electronic Protection auto reset 100 240V 100 240V 45 65Hz 45 65Hz 850W 3400W 1985W...

Page 16: ...rt on the front of the charger and insert the USB memory stick 7 Plug the AC power cord into the charger and switch ON AC power 8 Please allow up to 1 min for programming Programming is complete once...

Page 17: ...GC6A 220D AGM AGM 220 b13 Trojan Trojan T605 Flooded 210 b18 Trojan Trojan T875 Flooded Flooded 170 b19 US US2000 Flooded Flooded 216 b20 US US2200 Flooded Flooded 232 b21 US US250hc Flooded Flooded 2...

Page 18: ...sible Return and or Repair Policy Ifyouareexperiencinganyproblemswithyourunit pleasecontactourcustomerservicedepartmentatsupport enerdrive com au or Phone 1300 851 535 before returning product to reta...

Page 19: ...ENERDRIVE PTY LTD P O Box 9159 Wynnum Plaza Queensland Australia 4178 Ph 1300 851 535 Fax 07 3390 6911 Email support enerdrive com au Web www enerdrive com au...

Reviews: