The Enerdrive B-TEC Lithium Battery can deliver a very high discharge current due to the high power, high
quality Battery Management System (BMS) and prismatic Lithium cells inside the battery.
Refer to Section 10 - Battery Specifications for the maximum rated discharge current of your battery.
For this to happen, you MUST USE cable of the correct guage.
Inverter Usage
It is recommended to not put more load on your batteries than the rating of the BMS installed. We also
recommend following the below even if you have two batteries in parallel, this protects overloading a single
battery if the other battery in the bank was to shut down (i.e. low capacity).
•
12V 100AH B-TEC - 12V 1000W Inverter Max
•
12V 125AH B-TEC - 12V 1000W Inverter Max
•
12V 200AH B-TEC - 12V 2600W Inverter Max
•
12V 300AH B-TEC - 12V 3000W Inverter Max
•
24V 150AH B-TEC - 24V 3500W Inverter Max
Section 4 - Discharging (using the battery)
Enerdrive B-TEC G2 Manual (Rev. 3.1)