34
35
Anhang / Annex / Annexe / Anexo
BYTE 1:
Status code for normal operation modes
b7
b6
b5
b4
b3
b2
b1
b0
LOCK
VCR
SEQU
QUAD
CH4
CH3
CH2
CH1
b7
b6
b5
b4
b3
b2
b1
b0
CH4
CH3
CH2
CH1
CH4
CH3
CH2
CH1
Channel Select
1110 = CH1
1101 = CH2
1011 = CH3
0111 = CH4
Display Mode
0 = Quad screen display
1 = Full screen display
Auto-sequencing mode
0 = Auto sequencing mode
1 = Quad or full screen mode
VCR mode
0 = VCR operation
1 = Live operation
Security Lock mode
0 = Security lock ON mode
1 = Security lock OFF mode
Menu Setup mode
00 = Menu setup mode
BYTE 2:
Status code for alarm operations: The first 4 bits show the sensor activated alarm status of each channel; next 4 bits show the video loss alarm
status of each channel. The digit „1” means alarm event is detected, and „0” means no alarm event is detected,
b7 - b4: Sensor Activated Alarm
b3 - b0: Video Loss Alarm
Sensor activated Alarm
0001 = CH1 activated
0010 = CH2 activated
0100 = CH3 activated
1000 = CH4 activated
Video Loss Alarm
0001 = CH1 activated
0010 = CH2 activated
0100 = CH3 activated
1000 = CH4 activated