Echo monitoring
The Echos tab provides information on echo distortions
detected on the signal. When placing the mouse over an echo
representation, the following information is available:
●
Coefficient
: position of the path relative to main path.
●
Level
: level of the echo on the signal (expressed in dB)
●
Delay
: delay of the echo relative to the main path
(expressed in µs)
NOTE
: when the Echo information tab is displayed, the RF
constellation measurement is stopped. Constellation points will
therefore be reset.
Monitoring using thresholds and alarms
It is possible to configure alarms on parameter values measured for automated
monitoring.
●
Unlock the Threshold settings area using the button.
●
Enter the minimum and maximum values allowed for the
parameters you want to monitor.
●
Validate the threshold values by clicking the button. The
threshold settings area is grayed out and alarm-based
monitoring is enabled.
●
Automatically, red and green bars appear on the gauges to
indicate the range of alarm-raising and normal values
respectively.
●
As soon as a threshold is passed over, an alarm is raised and
transformed into a log event (Information-level logs).
ENENSYS DiviCatch RF - Manual
Page 24 / 40