20
www.enelx.com
Phone: +1-844-584-2329
1. Disassemble the Flexa system
Remove the end flex adapter by pushing
in the ring of the conduit fitting, and
pulling out the conduit.
2. Fit Flexa adapter into enclosure
box
Attach the top flex adapter into the hole
inside the service hatch with the
washer on the outside of the box, and
secure inside with the locking ring.
3. Attach Flexa conduit
Feed the Flexa conduit (not supplied)
from the rear left of the unit and press fit
into the flex adapter. Use the slots in the
rear channel to cable tie the conduit in
place if necessary.
415V 3PH
Copper Conductors Only
N
x
4. Feed through wiring
Pull the wires from the service disconnect
into the switchgear area running at least
12” (300mm) of wiring into the interior.
Connect the wires to the terminal block,
according to the wiring diagram inside the
service hatch. Also see section Wire and
Commission in this document.
To achieve the NEMA 3R rating, the
conduit must be fitted correctly into the
supplied fitting.
Check that the conduit is pressed firmly
into the flex adapters, and the locking
ring is secure.
Above ground conduit and wiring