Status at: May 2015
ESE 1408 DBG ES DIN
75
Malfunction
Possible cause
Correction
The test tip is not touching a
metallic blank location on the
device.
Hold the test tip on a metallic
blank location
Test lamp is defective
Call service staff.
The protective conductor is
defective.
Disconnect the device from
the generator.
The protective conductor is
missing.
Select the device with a pro-
tective earth.
Faults on the special equipment
The engine does not start in
remote start mode.
The remote start equipment
connecting plug is not insert-
ed properly.
Insert the remote start equip-
ment connecting plug correct-
ly.
The automatic choke lifting
magnet is defective.
Call service staff.
The remote start equipment
fuse is defective.
Replace the fuse.
The engine does not start in
external start mode.
The external start equipment
plug is not inserted properly.
Insert the external start
equipment plug correctly.
The high performance exter-
nal start fuse is defective.
Replace the fuse.
The battery is not charging in
charge retention mode.
The charge retention plug is
not inserted properly.
Insert the charge retention
plug correctly.
The charge retention fuse is
defective.
Replace the fuse.
Reduce idle speed does not
work.
Rocker switch is in the OFF
position.
Set the rocker switch to the
ON position.
The engine does not run for 5
minutes.
Wait for the minimum running
time since an engine start.
There is a load / electrical
device switched in.
Switch off load / electrical
device.
The lifting magnet for speed
lowering in idle is defective.
Call service staff.
Table 7.1: Difficulties operating the generator