Mounting
Screw in conical (
A
) or cylindrical (
B
) connection thread.
Align the housing of the electronics (potential equalization terminal of both devices
must point in the same direction).
Fix the housing in place.
Seal: to be provided by the customer
Mounting alternatives
A B
1 2
0000000014
10 Mounting alternatives
1
Welding sleeve G 1
2
Counternut G 1½
When using the G 1½ process connection (standard thread according to ISO 228-1,
hexagon SW55) and using the optional counternut, the device can be mounted flush
particularly easily, as it is a cylindrical thread. → 29
Mounting with welding sleeve G 1 (A)
‣
Screw in the device as far as it will go.
Mounting in existing thread G 1½ (B)
‣ Screw in the device flush with the inner wall and lock it with a G 1½ counternut.
• Seal: to be provided by the customer
• Suitable welding sleeve and counternut
→ 29 and order structure option "accessory enclosed"