Installation
Solitrend MMP40
12
Hauser
86 (3.39)
86 (3.39)
132 (5.2)
Ø108 (4
.25)
10
(0.39)
Ø6.5
(0.26)
1
A0037423
3
Mounting flange for round sensor, short version or round sensor, middle version
The mounting flange serves as a template for the mounting bore holes and the cut-out for
the sensor in the container:
1. Check the fit between the sensor and mounting flange
An installation pipe must first be mounted on the sensor before the mounting
flange can be fixed. The installation pipe is available in two different lengths and
can be ordered together with the device via the "Accessory mounted" (option NA)
or "Accessory enclosed" (option PA) section of the product order structure.
2. Make the cut-out in the container
5.3
Mounting location for round sensor, long version
The long version of the round sensor can be installed on the bottom or on the side wall of a
mixer using a mounting frame.
5.3.1
Mounting frame
A mounting frame is available for the long version of the round sensor. The frame can be
welded onto the floor or side wall of the vessel. At the clamping ring, the sensor can be
adjusted to the correct height or position using adjusting screws and nuts.
A0037425
4
Mounting frame with clamping ring for round sensor, long version
Summary of Contents for Solitrend MMP40