Soliphant FTM 32 DR
The Soliphant FTM 32 DR with rope if e.g.
– only top-mounting is possible
– there is strong build-up on the silo wall
– there is strong vibration of the silo
Take into account the angle of the mound or outflow funnel:
– for calculating the required length of the sensor when ordering a Soliphant
FTM 32 DR
– for calculating the length of mounting nozzle required and mounting point,
if you have an instrument with a specific length.
The Soliphant FTM32 DR may be shortened (with rope shortening set accessory).
The rope length cannot be increased.
The instrument should not be installed at the centre of the hopper but as near to the
vessel wall as possible in order to keep tension caused by discharging material to a
minimum. It should not, however, be so close that it touches the wall when it swings.
Check the stability of the roof and the tension acting on the rope. The tension caused
by material outflow is usually much higher with powders than with granular materials.
The Soliphant must be mounted outside the material stream when using pneumatic
conveying systems.
a)
b)
c)
d)
e)
f)
BA17
5
Y05
Fig. 5
Left:
correct mounting
a) next to the silo wall,
but with enough distance
from it and from material
build-ups
b) protected against material
flow
Right:
incorrect mounting
c) too near to the wall
and material build-up
d) in the centre of
the discharge hopper
e) in filling curtain
f) laterally mounted
3 Installation
FTM 30 DR, FTM 31 DR, FTM 32 DR
10