Prothermo NMT532
Operation
Hauser
51
8.3.5
Element position 2: VH46 to VH49 (VH40 to VH45 are not
available in NMT532)
Code
Display
Details
VH46
Hysteresis Width
(Hysteresis width)
Item type
Read / Write
Default
10 mm (0.39 in)
Range
0 to 99
999 mm
Sets the hysteresis of an element switch position.
Hysteresis entered as an offset value can prevent hunting caused by
fluctuations of the level surface. This changes according to the range of
fluctuations.
VH47
Clear Memory
(Memory deletion)
Item type
Selection
Default
None (0)
Range
0 to 99
999 mm
Selection
None, Clear
Resets the matrix parameter to the default setting.
VH48
Gas Offset
(Gas offset)
Item type
Read / Write
Default
300 mm (11.81 in)
Range
0 to 99
999 mm
When a temperature element in the gas (vapor) phase is within the
shown range below, it is not used for average gas temperature
calculations.
1
2
3
4
5
7
a
6
A0038550
36
Gas offset
a
VH48 gas offset 300 mm (11.81 in) (Default)
1
To NMT532 converter
2
Temperature element
3
Gas phase
4
Exclusion range (see Note)
5
Level
6
Liquid phase
7
To tank bottom
Although temperature elements in this range are in the gas
phase, they are excluded from average gas temperature
calculations in order to avoid effects from the interface between
the liquid phase and the gas phase.
VH49
Liquid Offset
(Liquid offset)
Item type
Read / Write
Default
300 mm (11.81 in)
Summary of Contents for Prothermo NMT532
Page 72: ...www addresses endress com...