Diagnostics and troubleshooting
Proservo NMS83
122
Hauser
Diagnostic
number
Short text
Remedy instructions
Status
signal
[from the
factory]
Diagnostic
behavior
[from the
factory]
Diagnostic of configuration
400
AIO simulation output
Deactivate simulation AIO output
C
Warning
401
DIO simulation output
Deactivate simulation DIO output
C
Warning
403
Calibration AIO
1. Restart device
2. Change I/O module
F
Alarm
404
Calibration AIP
1. Restart device
2. Change I/O module
F
Alarm
405
COMM timeout DIO 1 to 8 1. Check wiring
2. Change I/O module
F
Alarm
406
IOM offline
1. Check wiring
2. Change I/O module
F
Alarm
407
COMM timeout AIO 1 to 2 1. Check wiring
2. Change I/O module
F
Alarm
408
Invalid range AIO 1 to 2
1. Check device configuration.
2. Check wiring.
C
Warning
409
RTD temp out of range 1
to 2
1. Check electronic modules
2. Change I/O or main electronic
module
C
Warning
410
Data transfer
1. Check connection
2. Retry data transfer
F
Alarm
411
Hart device 1 to 15 has
malfunction
1. Check wiring
2. Change I/O module
F
Alarm
412
Processing download
Download active, please wait
C
Warning
413
NMT 1 to 15: element is
open or short
1. Check NMT wiring connection
2. Replace NMT
C
Warning
415
Hart device 1 to 15 offline 1. Check wiring
2. Change I/O module
C
Warning
434
Real time clock defective
Replace main electronics
C
Warning
436
Date/Time incorrect
Check date and time settings.
M
Warning
437
Configuration
incompatible
1. Restart device
2. Contact service
F
Alarm
438
Dataset
1. Check data set file
2. Check device configuration
3. Up- and download new
configuration
M
Warning
441
AIO 1 to 2 current output
alarm
1. Check process
2. Check current output settings
F
Alarm
442
AIO 1 to 2 current output
warning
1. Check process
2. Check current output settings
C
Warning
443
AIO 1 to 2 Input not HART
compatible
AIO select compatible HART input. C
Warning
484
Failure mode simulation
Deactivate simulation
C
Alarm
495
Diagnostic event
simulation
Deactivate simulation
C
Warning
560
Calibration mandatory
1. Carry out weight calibration
2. Carry out reference calibration
3. Carry out drum calibration
C
Alarm
585
Simulation distance
Deactivate simulation
C
Warning
586
Record map
Recording of mapping
please wait
C
Warning
Summary of Contents for Proservo NMS83
Page 317: ......