Proservo NMS83
Operating menu
Hauser
231
Tertiary variable (TV)
Navigation
Setup → Advanced setup → Communication → HART output → Configuration
→ Tertiary var(TV)
Prerequisite
≠
None
Additional information
Read access
Operator
Write access
-
Assign QV
Navigation
Setup → Advanced setup → Communication → HART output → Configuration
→ Assign QV
Description
Assigns a tank variable to the fourth HART variable (QV).
Selection
• Tank level
• Liquid temperature
• Vapor temperature
• Water level
• P1 (bottom)
• P2 (middle)
• P3 (top)
• Observed density value
• Volume
• Flow velocity
• Volume flow
• Vapor density
• Middle density
• Upper density
• Correction
• Tank level %
• GP 1 ... 4 value
• Measured level
• P3 position
• Tank reference height
• Local gravity
• P1 position
• Manual density
• Tank ullage
• Average profile density
• Lower density
• Upper interface level
• Lower interface level
• Bottom level
• Displacer position
• HART device 1 ... 15 PV
• HART device 1 ... 15 SV
• HART device 1 ... 15 TV
• HART device 1 ... 15 QV
• HART device 1 ... 15 PV mA
• HART device 1 ... 15 PV %
Summary of Contents for Proservo NMS83