Proline Promass 84F
52
Hauser
Rupture disk
Sensor housings with integrated rupture disks are optionally available.
#
Warning!
• Make sure that the function and operation of the rupture disk is not impeded through the installation.
Triggering overpressure in the housing as stated on the indication label. Take adequate precautions to ensure
that no damage occurs, and risk to human life is ruled out, if the rupture disk is triggered.
Rupture disk: Burst pressure 10 to 15 bar (145 to 217 psi).
• Please note that the housing can no longer assume a secondary containment function if a rupture disk is used.
• It is not permitted to open the connections or remove the rupture disk.
"
Caution!
• Rupture disks can not be combined with separately available heating jacket.
• The existing connection nozzles are not designed for a rinse or pressure monitoring function.
!
Note!
• Before commissioning, please remove the transport protection of the rupture disk.
• Please note the indication labels.
A0008361
DN 8 to DN 150 (3/8" to 6")
1
Indication label for the rupture disk
2
½" NPT internal screw thread with 1" width across flat
3
Transport protection
L
H
45°
F
G
E
Z
Z
1
2
3
RUPTURE DISK
12,5 BAR +/-10%@80°C
i
DN
E
F
G
H
L
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
8
3/8"
ca. 42
ca. 1.65
AF 1"
½"-NPT
62
2.44
216
8.50
15
½"
ca. 42
ca. 1.65
AF 1"
½"-NPT
62
2.44
220
8.66
25
1"
ca. 42
ca. 1.65
AF 1"
½"-NPT
62
2.44
260
10.24
40
1½"
ca. 42
ca. 1.65
AF 1"
½"-NPT
67
2.64
310
12.20
50
2"
ca. 42
ca. 1.65
AF 1"
½"-NPT
79
3.11
452
17.78
80
3"
ca. 42
ca. 1.65
AF 1"
½"-NPT
101
3.98
560
22.0
100
4"
ca. 42
ca. 1.65
AF 1"
½"-NPT
120
4.72
684
27.0
150
6"
ca. 42
ca. 1.65
AF 1"
½"-NPT
141
5.55
880
34.6