Proline t-mass 65F, 65I
Hauser
19
Operating conditions: Process
Medium temperature range
Sensor
t-mass F:
–40 to +100°C (–40 to 212°F)
t-mass I:
–40 to +130°C (–40 to 266°F)
Seals:
t-mass F:
Viton –20°C to +100°C (–4°F to +212°F)
Kalrez –20°C to +100°C (–4°F to +212°F)
EPDM –40°C to +100°C (–40°F to +212°F)
t-mass I:
Nitrile –35°C to +130°C (–3°F to +266°F)
Kalrez –20°C to +130°C (–4°F to +266°F)
EPDM –40°C to +130°C (–40°F to +266°F)
Pressure loss
2 mbar (0.029 psi) maximum (without flow conditioner)
Medium pressure range (nom-
inal pressure)
t-mass F:
–0.5 to 40 bar gauge (–7.25 to 580 psig)
t-mass I:
–0.5 to 20 bar gauge (–7.25 to 290 psig)
Medium pressure
Pressure temperature curve to EN (DIN), stainless steel
a0005240
Pressure temperature curve to JIS B2238 and ANSI 16.5, stainless steel
a0005241
-200 -100
0
5
10
15
20
25
30
35
40
45
0
100
200
300
400
°C
bar
PN 16/40
PN 40
PN 16
-300 -100
0
200
400
600
800
1000
1200
0 100
300
700
°F
psi
Class 150/300
Cl. 150
Cl. 300
-200 -100
0
5
10
15
20
25
30
35
40
45
0
100 200 300 400
°C
bar
10/40 K
20 K
10 K
1400
1600
500