Ordering information
NOTE: Hauser reserves the right to change or modify product, specifications, and ordering informa-
tion at any time without notice. Please consult Hauser or your local representative for the most recent
information.
The EHauser service organization can provide detailed ordering information and information on the
order codes on request.
To ensure each meter is programmed to individual requirements, the following information is essential:
• Gas type if not air (composition if more than one gas in % volume)
• Gas pressure
• Gas temperature
• Line size - internal diameter in metric or US units
• 20 mA range required
• Flow engineering units (kg/h, lb/h etc.)
T-masss 65F -
010 020 030 040 050 060 070 080 090 100 110 120
Nominal diameter
15
1/2” (DN15)
25
1” (DN25)
40
1-1/2” (DN40)
50
2” (DN 50)
80
3” (DN80)
1H
4” (DN100)
010
Tube material / sensor material
A
316L SS / 316L SS
B
316L SS / Alloy C22
020
Process connection
K
ANSI Class 150 flange, RF, Sch. 40
L
ANSI Class 150 flange, RF, Sch. 80
M
ANSI Class 300 flange, RF, Sch. 40
N
ANSI Class 300 flange, RF, Sch. 80
030
Seal
2
Viton, -4 to +212°F (-20 to +100°C)
3
Kalrez, -4 to +212°F (-20 to +100°C)
4
EPDM, -40 to +212°F (-40 to +100°C)
040
Surface finish
A
Basic version
B
Cleaned/degreased for Oxygen service
050
Calibration
G
Factory calibration, w/o flow conditioner delivered
H
Factory calibration with flow conditioner
K
Factory calibration, traceable; w/o flow conditioner delivered;
ISO/IEC 17025
L
Factory calibration, traceable; with flow conditioner delivered;
ISO/IEC 17025
060
Additional test, certificate
1
Without additional test
2
Material certificate (tube + sensor)
3
Pressure test
4
Material certificate (tube + sensor) plus pressure test
5
CRN approval (only for ANSI flanges)
8
CRN ap material certificate (tube + sensor) plus
pressure test (only for ANSI flanges)
070
Approval
A
Non-hazardous
N
FM XP Cl. I, Div. 1 / CSA Cl. I, Div. 1, Grps A-D + Zone 1
(not for housing C)
R
FM NI CL, I, Div. 2 / CSA Cl. I, Div. 2, Grps A-D + Zone 2
(not for housing G, not for output/input R, S, T, U)
T-masss 65F Flange Version
080
Housing
A
Compact aluminum, NEMA 4X
C
Wall mount aluminum, NEMA 4X
G
Field housing aluminum, NEMA 4X (not for approvals A, R)
1
Compact aluminum, NEMA 4X, -40°F
3
Wall mount aluminum, NEMA 4X, -40°F
7
Filed housing aluminum, NEMA 4X, -40°F
090
Cable entry
B
1/2” NPT
X
Not used, sensor only (only for housing A)
100
Display, operation
7
85 to 260 VAC, without display, remote configuration
(not for housing C)
8
20 to 55 VAC / 16 to 62 VDC without display, remote
configuration (not for housing C)
A
85 to 260 VAC, 2-line display plus push buttons
B
20 to 55 VAC / 16 to 62 VDC, 2-line display plus push buttons
X
Sensor only
110
Software
B
Factory setup; air
C
1 channel; standard gas / mixture
D
2 channel; standard gas / mixture
E
1 channel; special gas / mixture
F
2 channel; special gas / mixture
X
Sensor only
120
Output, input
Fixed I/O modules
A
4 to 20 mA HART + frequency
B
4 to 20 mA HART + fre two relays
J
Profibus-DP
Q
MODBUS RS 485
R
4 to 20 mA HART + 0/4 to 20 mA, passive, Ex-i
(not for approval A, R)
S
4 to 20 mA HART frequency passive, Ex-i
(not for approval A, R)
T
4 to 20 mA HART + frequency passive, Ex-i (not for approval A, R)
U
4 to 20 mA HART + 0/4 to 20 mA, passive, Ex-i
(not for approval A, R)
Flexible I/O modules
2
4 to 20 mA HART + fre relay + 20 mA input
5
4 to 20 mA HART + fre 20 mA input + status input
6
4 to 20 mA HART + status input + 20 mA input (1 x out, 1 x in)
8
4 to 20 mA HART + 20 mA input + fre status input
X
Sensor only