Electrical connection
Proline Promass F 300 EtherNet/IP
48
1
2
3
4
5
6
7
8
128
64
32
16
8
4
2
1
IP A
ddr
ess se
tting
(las
t
oc
te
t)
A0029635
1. Depending on the housing version, loosen the securing clamp or fixing screw of the
housing cover.
2. Depending on the housing version, unscrew or open the housing cover and
disconnect the local display from the main electronics module where necessary.
3. Set the desired IP address using the corresponding DIP switches on the I/O
electronics module.
4. Reverse the removal procedure to reassemble the transmitter.
5. Reconnect the device to the power supply.
The configured device address is used once the device is restarted.
7.5.2
Activating the default IP address
The DHCP function is enabled in the device at the factory, i.e. the device expects an IP
address to be assigned by the network. This function can be disabled and the device can be
set to the default IP address 192.168.1.212 by DIP switch.
Activating the default IP address via the DIP switch
Risk of electric shock when opening the transmitter housing.
‣
Before opening the transmitter housing:
‣
Disconnect the device from the power supply.
On
Off
4
3
1
2
A0034499
1. Depending on the housing version, loosen the securing clamp or fixing screw of the
housing cover.
2. Depending on the housing version, unscrew or open the housing cover and
disconnect the local display from the main electronics module where necessary .
3. Set DIP switch No. 2 on the I/O electronics module from
OFF
→
ON
.
4. Reverse the removal procedure to reassemble the transmitter.
5. Reconnect the device to the power supply.