Identification

Loop-powered display unit

6

2.3 

Workplace safety

For work on and with the device:

Wear the required personal protective equipment according to federal/national

regulations.

2.4 

Operational safety

Risk of injury!

Operate the device in proper technical condition and fail-safe condition only.

The operator is responsible for interference-free operation of the device.

Conversions to the device

Unauthorized modifications to the device are not permitted and can lead to

unforeseeable dangers.

If modifications are still required, consult with the supplier.

Repair

To ensure continued operational safety and reliability,

Carry out repairs on the device only if they are expressly permitted.

Observe federal/national regulations pertaining to repair of an electrical device.

Use only original spare parts and accessories.

Hazardous area

To eliminate the risk of danger to persons or the facility when the device is used in the

approval-related area (e.g. explosion protection, pressure equipment safety):

Check the nameplate to verify if the device ordered can be put to its intended use in

the approval-related area.

Observe the specifications in the separate supplementary documentation that is an

integral part of these Instructions.

2.5 

Product safety

This measuring device is designed in accordance with good engineering practice to

meet state-of-the-art safety requirements, has been tested, and left the factory in a

condition in which it is safe to operate.
It meets general safety standards and legal requirements. It also complies with the EC

directives listed in the device-specific EC Declaration of Conformity. The manufacturer

confirms this by affixing the CE mark to the device.

Identification

3.1 

Nameplate

The nameplate is located on the right-hand side of the housing in the case of the field

device, and on the rear of the housing in the case of the panel-mounted device.

Summary of Contents for ORIA15

Page 1: ...n ORIA15 These instructions are Brief Operating Instructions they do not replace the Operating Instructions included in the scope of supply For detailed information refer to the Operating Instructions...

Page 2: ...uctions 9 4 4 Post installation check 13 5 Wiring 13 5 1 Quick wiring guide 14 5 2 Connection in 4 to 20 mA mode 15 5 3 Connection in HART mode 16 5 4 Inserting the cable field housing 22 5 5 Shieldin...

Page 3: ...lows A0011200 Ground connection A grounded terminal which as far as the operator is concerned is grounded via a grounding system A0011199 Protective ground connection A terminal which must be connecte...

Page 4: ...96 Reference to graphic Refers to the corresponding graphic number and page number Series of steps Result of a sequence of actions 1 1 4 Symbols in graphics Symbol Meaning 1 2 3 Item numbers Series of...

Page 5: ...the Operating Instructions and supplementary documentation as well as in the certificates depending on the application Following instructions and basic conditions 2 2 Designated use The process displa...

Page 6: ...eliminate the risk of danger to persons or the facility when the device is used in the approval related area e g explosion protection pressure equipment safety Check the nameplate to verify if the dev...

Page 7: ...l Fastening fixtures HART communication resistance module optional Field device Process display unit Brief Operating Instructions Operating Instructions on CD ROM Ex Safety Instructions optional Faste...

Page 8: ...ceipt of the goods check the following points Is the packaging or the content damaged Is the delivery complete Compare the scope of delivery against the information on your order form 4 1 2 Transport...

Page 9: ...762 1 Installation instructions for the panel housing Installation in a panel with a panel cutout 92x45 mm 3 62x1 77 in max panel thickness 13 mm 0 51 in 1 Slot the device into the panel cutout from t...

Page 10: ...ting 2 Weather protection cover optional 1 Release the 4 housing screws 2 Open the housing 3 Secure the mounting plate to the rear of the device with 4 screws supplied The optional weather protection...

Page 11: ...bore holes 82 mm 3 23 in apart and secure the plate on the wall with 2 screws not supplied 2 Open the housing 3 Secure the display unit on the mounting plate with the 4 screws supplied 4 Close the co...

Page 12: ...ion Accessories in the relevant Operating instructions A0020785 4 Mounting the optional HART communication resistance module 1 Unplug the pluggable terminal block 2 Plug terminal block into the suitab...

Page 13: ...1 Display unit in the panel mount housing Is the seal undamaged Are the mounting clips securely fastened on the housing of the device Are the threaded rods properly tightened Is the device located in...

Page 14: ...r Panel housing The terminals are located on the rear of the housing Field housing The terminals are located inside the housing The device has two M16 cable entries The housing must be opened for wiri...

Page 15: ...owing diagrams show how the process display unit is connected in 4 to 20 mA mode Connection without backlighting Connection with backlighting Connection with transmitter power supply and transmitter L...

Page 16: ...the 4 to 20 mA circuit 2 I Y LED A0017708 2 4 to 20 mA power source 2 I Y LED A0017709 2 4 to 20 mA power source 5 3 Connection in HART mode The following diagrams show how the process display unit is...

Page 17: ...process display unit and loop power supply without backlighting Y I Rs DC 1 2 3 LED A0019567 1 Sensor 2 Power supply 3 HART resistance 2 wire sensor with process display unit and loop power supply wit...

Page 18: ...ent meter optional 3 Sensor 4 Power supply 4 wire device Current output with process display unit and actuator e g actuator valve without backlighting 1 3 2 LED A0019573 1 Actuator 2 Power supply 4 wi...

Page 19: ...wire sensors with process display unit and loop power supply with backlighting Rs DC 1 2 3 I Y Y I Y I LED A0019722 1 Sensors 2 Power supply 3 HART resistance Optional HART communication resistance m...

Page 20: ...t and loop power supply without backlighting 1 LED 3 2 Y I Rs DC A0020839 1 HART communication resistance module 2 Sensor 3 Power supply 2 wire sensor with process display unit and loop power supply w...

Page 21: ...er supply without backlighting 1 3 Y I 2 LED A0020837 1 HART communication resistance module 2 Power supply of 4 wire device 3 Sensor 4 wire sensor with process display unit and loop power supply with...

Page 22: ...the cable 4 Connect the cable incl functional grounding and close the cable gland 5 5 Shielding and grounding Optimum electromagnetic compatibility EMC can only be guaranteed if the system components...

Page 23: ...grounded on one side only i e it must not be connected to the ground terminal of the housing The shield that is not connected should be insulated 5 6 Connecting to functional grounding 5 6 1 Panel mo...

Page 24: ...s protection is guaranteed after mounting or servicing the device The housing seal must be clean and undamaged when inserted into the groove The seal must be cleaned dried or replaced if necessary The...

Page 25: ...ndition and specifications Notes Are cables or the device damaged Visual inspection Electrical connection Notes Does the supply current match the specifications on the nameplate Are the mounted cables...

Page 26: ...of a user code the individual menus and parameters can be displayed but not changed To change a parameter the user code must be entered As the display unit can only display digits in the 7 segment di...

Page 27: ......

Page 28: ......

Reviews: