5.2.2
Useful lifetime of electric components
The established failure rates of electrical components apply for a useful lifetime of 12 years as
per IEC 61508-2: 2010, section 7.4.9.5, note 3.
The device's year of manufacture is coded in the first character of the serial number (→ table
below).
Example: serial number
L
5ABBF02000 → year of manufacture 2016
ASCII character
Meaning
ASCII character
Meaning
ASCII character
Meaning
D
2010
K
2015
R
2020
E
2011
L
2016
S
2021
F
2012
M
2017
T
2022
H
2013
N
2018
V
2023
J
2014
P
2019
W
2024
5.2.3
Suitability of the measuring device
1. Carefully select the nominal diameter of the measuring device in accordance with the
application's expected flow rates.
The maximum flow rate during operation must not exceed the specified maximum
value for the sensor.
2. In safety-related applications, it is advisable to select a limit value for monitoring the
minimum flow that is not less than 5 % of the specified maximum value of the sensor.
NOTICE
Use the measuring device according to the specifications.
‣
Pay attention to the medium properties and the environmental conditions.
‣
Carefully follow instructions pertaining to critical process situations and installation
conditions.
Detailed information on:
• Installation
• Electrical connection
• Medium properties
• Environment
• Process
Operating Instructions and Technical Information → 11