Source container FQG66
Electrical connection
Hauser
23
6.1.4
Potential equalization
Terminal on the sign holder, see the following graphic:
A0026837
Potential equalization: max. 4 mm
2
(12 AWG)
6.1.5
Connection data
• Nominal voltage: 8 V
DC
• Current consumption of "EIN/ON" proximity switch
• "EIN/ON" switch position = ≤1 mA
• "AUS/OFF" switch position = ≥3 mA
• "AUS/OFF" proximity switch
• "EIN/ON" switch position = ≥3 mA
• "AUS/OFF" switch position = ≤1 mA
6.1.6
Isolating amplifiers
The following isolating amplifiers, for example, can be connected for signal evaluation:
• Nivotester FTL325N (Hauser)
• KFD2-SH-Ex1, 24 V
DC
(Fuchs)