XA00097D
Proline Promass 80
26
Hauser
Approvals (Pos. no. 13 in type code)
Housing (Pos. no. 14 in type code)
Cable entry (Pos. no. 15 in the type code)
Inputs/outputs (Pos. no. 18 in the type code)
!
Note!
For a detailed explanation of these values, regarding the available outputs and inputs, as well as a description
of the associated terminal assignments and connection data:
*
Type of explosion protection
Transmitter
Sensor
Remote
Compact
Ex ia
Compact
non-intrinsically safe
B
Ex d[ia Ga] IIC T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia Ga] IIC T1-T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia] IIC T1-T6 Gb
Ex tb IIIC T** Db
Ex ia IIC T1-T6 Gb
Ex ia tb IIIC T** Db
Promass A
Promass E
Promass F
Promass F(HT)
Promass H
Promass I
Promass M
Promass P
Promass S
DN1…4
DN8…50
DN8…50
DN25…50
DN8…40
DN8…40
DN8…50
DN8…40
DN8…40
D
Ex de[ia Ga] IIC T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia Ga] IIC T1-T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia] IIC T1-T6 Gb
Ex tb IIIC T** Db
Ex ia IIC T1-T6 Gb
Ex ia tb IIIC T** Db
C
Ex d[ia Ga] IIB T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia Ga] IIB T1-T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia] IIB T1-T6 Gb
Ex tb IIIC T** Db
Ex ia IIB T1-T6 Gb
Ex ia tb IIIC T** Db
Promass E
Promass F
Promass F(HT)
Promass H
Promass I
Promass M
Promass P
Promass S
DN80
DN80…250
DN80
DN50
DN40FB…80
DN80
DN50
DN50
E
Ex de[ia Ga] IIB T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia Ga] IIB T1-T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia] IIB T1-T6 Gb
Ex tb IIIC T** Db
Ex ia IIB T1-T6 Gb
Ex ia tb IIIC T** Db
F
Ex d[ia Ga] IIC T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia Ga] IIC T1-T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia] IIC T1-T6 Gb
Ex tb IIIC T** Db
Ex ia IIC T1-T6 Gb
Ex ia tb IIIC T** Db
G
Ex de[ia Ga] IIC T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia Ga] IIC T1-T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia] IIC T1-T6 Gb
Ex tb IIIC T** Db
Ex ia IIC T1-T6 Gb
Ex ia tb IIIC T** Db
1
Ex d[ia Ga] IIC T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia Ga] IIC T1-T6 Ga/Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia] IIC T1-T6 Ga/Gb
Ex tb IIIC T** Db
Ex ia IIC T1-T6 Ga/Gb
Ex ia tb IIIC T** Db
Promass F
1)
Promass F(HT)
1)
DN80…250
DN80
2
Ex de[ia Ga] IIC T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia Ga] IIC T1-T6 Ga/Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia] IIC T1-T6 Ga/Gb
Ex tb IIIC T** Db
Ex ia IIC T1-T6 Ga/Gb
Ex ia tb IIIC T** Db
4
Ex d[ia Ga] IIB T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia Ga] IIB T1-T6 Ga/Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia] IIB T1-T6 Ga/Gb
Ex tb IIIC T** Db
Ex ia IIB T1-T6 Ga/Gb
Ex ia tb IIIC T** Db
6
Ex de[ia Ga] IIB T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia Ga] IIB T1-T6 Ga/Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia] IIB T1-T6 Ga/Gb
Ex tb IIIC T** Db
Ex ia IIB T1-T6 Ga/Gb
Ex ia tb IIIC T** Db
3
Ex d[ia Ga] IIC T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia Ga] IIC T1-T6 Ga/Gb
Ex tb [ia Da] IIIC T** Db
Ex d[ia] IIC T1-T6 Ga/Gb
Ex tb IIIC T** Db
Ex ia IIC T1-T6 Ga/Gb
Ex ia tb IIIC T** Db
Promass F
1)
Promass F(HT)
1)
DN8…50
DN25…50
5
Ex de[ia Ga] IIC T6 Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia Ga] IIC T1-T6 Ga/Gb
Ex tb [ia Da] IIIC T** Db
Ex de[ia] IIC T1-T6 Ga/Gb
Ex tb IIIC T** Db
Ex ia IIC T1-T6 Ga/Gb
Ex ia tb IIIC T** Db
HT = High temperature
1)
For the sensors Promass F DN 8 to 250, Promass F(HT) DN 25, 50, 80 Zone 0 is permitted in the measuring pipe
*
Type
Min. ambient temperature T
a min
A, L
Compact
–20 °C
1, 4, M, N
–40 °C
E, F, J, K
Remote
–20 °C
7, 8
–40 °C
*
Thread (cable entry)
A
M20
1.5
B
NPT ½"
C
G ½"
*
Type of protection
A, D, 8
non-intrisically safe outputs
S, T
Ex ia
Summary of Contents for ATEX II1/2GD
Page 20: ...0ATEX II2GD II1 2GD IECEx Zone 1 Zone 21 Zone 0 1 Proline Promass 80 20 Endress Hauser ...
Page 21: ...Proline Promass 80 ATEX II2GD II1 2GD IECEx Zone 1 Zone 21 Zone 0 1 0 Endress Hauser 21 ...
Page 49: ...Proline Promass 80 XA00097D Endress Hauser 49 ...
Page 50: ...www endress com worldwide XA00097D 06 A3 14 12 71146622 FM SGML 9 0 ...