3.2 Connect Additional TDS-6 Time Distribution Server Extension
Units
, continued
Procedure
Follow these steps to chain additional TDS-6 Time Distribution Server
extension units.
Step 1.
Position TDS-6 unit
Fix unit firmly in a position where chain cable will reach a functioning TDS-
6 unit CHAIN outlet without strain or obstruction.
Check cable run to intended destination to ensure sufficient length to
chained TDS-6 unit.
Step 2.
Chain to Functioning TDS-6 Unit
Connect supplied cable to functioning TDS-6 unit CHAIN 2 outlet and
connect other end to CHAIN 1 input on the new TDS-6 unit.
Step 3.
Inspect TDS-6 unit operating status
On front of new unit, check the power LED is ON and status LED’s are
flashing for:
•
PPS
•
SERIAL
On the back of the unit, check the PPS LED is flashing constantly.
NOTE: If the LED’s are not flashing check the TDS-2 module is powered
and operating, or check connections. In the event of a function failure
contact Endace support;