2.2.1 Connect TDS-2 Module to Electrical Mains Power Source
Description
The TDS-2 module accepts electrical mains power using an optional
AC/DC adapter.
Procedure
Follow this step to connect the TDS-2 module to mains power source.
No. Step
Key
Points
1. Connect
to
mains
power.
Connect TR36A12 AC/DC adapter to a mains
power source via a suitable IEC 32/C8 cable.
Connect the TR36A12 2.5mm DC plug to the
receptable on TDS-2 module back-plate.
2.2.2 Connect TDS-2 Module to 12V DC Power Source
Description
For connection of the TDS-2 module directly to a 12V DC power source
the polarity is indicated on the rear face of the module, directly below the
12V DC power receptable.
The TDS-2 module has an internal reverse polarity protection diode but no
fuse protection.
Procedure
Follow this step to connect the TDS-2 unit to the 12 volt DC power
source.
Step 1
Connect DC Power Source
Run a suitable lead from the 12V power source to TDS-2 module and fit
a 2.5mm DC coaxial plug.
CAUTION: If the module is being fitted to an unprotected power source,
an external fuse of 2 amps value is required.
2.3 Connect TDS-2 Module to Code Division Multiple Access
Source
Description
An RJ45 cable is used to connect a TDS-2 module to a CDMA source via
an adapter supplied with the CDMA receiver.
The module signal source selection switch is set to CDMA and the LED
flashes indicate processes are occurring in relation to timing signal and
SERIAL packet activity.