Endace Measurement Systems
®
Ltd
http://www.endace.com
EDM05.05-01r1 TDS-2 Module TDS-6 Unit User Manual
Copyright© All rights reserved
8
Version 2. 22 September 2005.
2.3 Connect TDS-2 Module to Code Division Multiple Access
Source
, continued
Procedure
Follow these steps to connect the code division multiple access source.
Step 1
Connect CDMA Receiver
Connect RJ45 cable from CDMA receiver to DB9-to-RJ45 adapter supplied
with CDMA kit.
Set signal source selection switch to CDMA.
CAUTION: Only use the DB9-to-RJ45 adapter supplied with CDMA
receiver otherwise damage will occur to the equipment.
Step 2
Check Timing Signal.
When CDMA unit locks onto the network, the CDMA receiver’s LEDs
activate, with the PPS LED flashing once per second indicating the timing
signal is being received.
The PPS LED on the TDS-2 front faceplate should now be flashing.
2.4 Connect TDS-2 Module to Global Positioning System Time
Signal Source
Description
The TDS-2 module is connected by cable to the GPS receiver signal
source and the signal source selection switch is set to GPS.
After 5-15 minutes the GPS antenna locks onto the GPS satellites and the
activity LEDs start flashing.
Procedure
Follow these steps to connect TDS-2 module to global positioning time
signal source.
Step 1
Connect GPS Receiver
Connect GPS receiver to the TDS-2 module GPS signal input using the
cable and Endace supplied adapter.
The TDS-2 automatically supplies DC power through this cable to the
antenna.
Continued on next page