EDM 01-17 DAG 7.1S Card User Guide
PoS OC12 Stream Example
An example for a card locked to a PoS OC-12 stream is on ports C and D,
ports A and B are unused:
Port LOS LOF OOF B1 B2 B3 REI
C2
PTR
A: 1 1 1
0
0
0
0
0xe800 lop
B: 1 1 1
0
0
0
0
0xe800 lop
C: 0 0 0
0
0
0
0
0xcf00
valid
D: 0 0 0
0
0
0
0
0xcf00
valid
An example of a card set to OC-3 PoS while the line carries OC-12 PoS
is:
Port LOS LOF OOF B1 B2 B3 REI
C2
PTR
C: 1 0 1 1 1 1 1
0xfd00 lop
D: 1 0 1 1 1 1 1
0x0100 lop
Port LOS LOF OOF B1 B2 B3 REI
C2
PTR
C: 1 0 1 1 1 1 1
0xe200 Lop
D: 1 0 1 1 1 1 1
0x5300 Lop
ATM Cell Stream Example
An example for an ATM cell stream at OC-12 is, ports A and B are unused:
Port LOS LOF OOF B1 B2 B3 REI
C2
PTR
A: 1 1 1 0 0 0 0 0xe800 lop
B: 1 1 1 0 0 0 0 0xe800 lop
C: 0 0 0 0 0 0 0 0x1300
valid
D: 0 0 0 0 0 0 0 0x1300
valid
No error bits are raised in dagconfig –s1 if the card is configured to PoS
when on an ATM link or vice versa.
Network is ATM :
•
C2 label should be
13
•
PTR should be
valid
•
Rest of the statistics should be
0
Version 2: May 2006
22
©2006
Summary of Contents for DAG 7.1S
Page 1: ......
Page 4: ......
Page 12: ...EDM 01 17 DAG 7 1S Card User Guide Version 2 May 2006 6 2006 ...
Page 16: ...EDM 01 17 DAG 7 1S Card User Guide Version 2 May 2006 10 2006 ...
Page 30: ...EDM 01 17 DAG 7 1S Card User Guide Version 2 May 2006 24 2006 ...
Page 36: ...EDM 01 17 DAG 7 1S Card User Guide Version 2 May 2006 30 2006 ...
Page 44: ...EDM 01 17 DAG 7 1S Card User Guide Version 2 May 2006 38 2006 ...
Page 50: ...EDM 01 17 DAG 7 1S Card User Guide Version 2 May 2006 44 2006 ...