Endace Measurement Systems.
http://www.endace.com
EDM01.05-10r1 DAG 4.3S Card User Manual
17
Revision 6. 22 September 2005.
4.4 DAG 4.3S Card Configuration Options
, continued
Status bits display,
continued
LOC
Loss of clock.
If set the clock recovery PLL is unable to lock onto
and recover the input data stream, check
connections and optical signal level.
LOR
Loss of reference.
If set the clock recovery PLL is unable to lock onto
the reference clock, check configuration.
LoP
Path loss of pointer.
If set indicates the path overhead processor is not
locked onto the SONET/SDH stream, check
connections and optical signal level.
PathBIP
SONET/SDH Path Bit Interleaved Parity error. The
link is impaired, check connections and optical
signal level.
PathREI
SONET/SDH Path Remote Error Indication. The
link is impaired, check connections and optical
signal level.
POS mode
In POS mode, the following columns are present:
RxFrames
Number of PoS frames received since last reading.
RxBytes
Number of PoS payload bytes received since last
reading.
ATM mode
In ATM mode, the following columns are present:
LCD
Loss of Cell Delineation. The framer cannot lock
onto the ATM cells.
RxCells
Number of non-idle ATM cells received since last
reading.
RxIdles
Number of idle ATM cells received since last
reading.
Continued on next page