4.3 Configuration in WYSYCC Style
Description
The configuration of the tool works in WYSYCC style – what you see you
can change.
To turn on the card’s laser on for instance, type:
dag@endace:~$ dagfour -d dag0 laser
light laser
link noreset OC48c nofcl noeql
sonet master scramble
POS crc32 nocrcstrip short=16 long=1536 discard nopscramble rxpkts txpkts
packet varlen slen=48
packetA drop=0
pcix 133MHz 64-bit nodrop routesource=stream0 buf=128MB rxstreams=1 txstreams=1 mem=128:0
ATM status
In ATM mode, the status output changes:
dag@endace:~$ dagfour -d dag0 atm
light laser
link noreset OC48c nofcl noeql
sonet master scramble
ATM discard pscramble rxpkts txpkts
packetA drop=0
pcix 133MHz 64-bit nodrop routesource=stream0 buf=128MB rxstreams=1 txstreams=1 mem=128:0
For configuration options removing or adding the "no" prefix will change
the setting.
4.4 DAG 4.3S Card Configuration Options
Description
There are many DAG 4.3S card configuration options supported.
default
set framer to normal defaults
[no]laser
dis/enable transmit laser
atm
set framer into ATM mode
pos
set framer into Packet-over-SONET (PoS) mode
[no]reset
hold/release framer (in) reset
oc48c
set framer to OC48c mode
[no]fcl
(un)set facility loop back in the phy. This is useful for
card chaining
[no]eql
(un)set equipment loop back in the phy
[no]scramble
(un)set SONET scrambling
Continued on next page