Endace Measurement Systems.
http://www.endace.com
EDM01.05-10r1 DAG 4.3S Card User Manual
11
Revision 6. 22 September 2005.
4.0 CONFIDENCE TESTING
Introduction
The confidence testing is a process to determine whether the DAG 4.3S
card is functioning correctly.
The process also involves a card capture session, and demonstrates
configuration in the style of 'What You See You Can Change', WYSYCC.
Interface statistics are also inspected during this process.
In this chapter
This chapter covers the following sections of information.
•
Interpreting DAG 4.3S Card LED Status
•
DAG 4.3S Card Capture Session
•
Configuration in WYSYCC Style
•
DAG 4.3S Card Configuration Options
•
Inspect Link Data
•
Reporting Problems
4.1 Interpreting DAG 4.3S Card LED Status
Description
When a DAG 4.3S card is powered up LED 1 should always illuminates.
The other LEDs display for specific functions. The DAG 4.3S has 6 status
LEDs, one is coloured blue, one yellow, two green, one orange, and one
red.
Figure
Figure 4-1 shows the DAG 4.3S status LEDs.
Figure 4-1. DAG 4.3S Card Status LEDs.
Continued on next page