PROGRAMMABLE AC/DC VOLTMETER
ENDA
EPV742
SET
LOCK
0.000
OUTPUT
250V AC 8A
RESISTIVE
LOAD
A
B
1
9
20
13
14
15
S
N
:
X
X
X
X
X
X
X
X
X
16
17
18
8
6
8
0
4
0
7
7
1
1
5
5
0
ENDA
INDUSTRIAL ELECTRONICS
EPV742
-230VA
C-R-RSI
PROGRAMMABLE AC/DC
VOLT
METER
CAT II
Made in Turkey
1
1
12
230V AC +10% -20%
50/60Hz
5
VA
M
a
x
.
1
0
0
V
A
C
/
D
C
M
a
x
.
5
0
0
V
A
C
/
D
C
+
+
1
9
20
13
14
15
S
N
:
X
X
X
X
X
X
X
X
X
16
17
18
8
6
8
0
4
0
7
7
1
1
5
5
0
ENDA
INDUSTRIAL ELECTRONICS
EPV742
-230VA
C
PROGRAMMABLE AC/DC
VOLT
METER
CAT II
Made in Turkey
1
1
12
230V AC +10% -20%
50/60Hz
5
VA
M
a
x
.
1
0
0
V
A
C
/
D
C
M
a
x
.
5
0
0
V
A
C
/
D
C
+
+
2/
4
A
-A
0
A
0
A
0
A
-A
A
0
A
0
A
-A
0
ac
ac.dc
dc
T
3T/2
T/2
2T
T
3T/2
T/2
2T
T
3T/2
T/2
2T
T
3T/2
T/2
0
T
3T/2
T/2
2T
T
3T/2
T/2
2T
d
d
T
2T
0.308 A
0.386 A
0.000
A
0.000
A
d
T
d
T
A
A
d
T
A
d
T
2
2
0.000
1
2
A
1
2
A
2
A 1
2
A
p
1
2
A
1
A
p
2
A 1
2
A
1
2
A 1
3
A 1
3
A 1
17
18
184-253V AC
50/60Hz 7VA
Switch
ac
Ac.dc
dc
(rms)
17
18
DIMENSIONS
Depth
Panel Cut-out
OUTPUT CHART
1)
2)
Panel thickness should be maximum
10
mm.
There must be at least
90
mm free space
behind the device
,
otherwise
it would be difficult
to remove it from the panel.
-
Push the flush-mounting
clamp in direction
1
as
shown in the figure left.
-
Then, pull out the clamp in
direction
2.
For removing mounting clamps
:
Flush mounting
clamp
Gasket
NOTE :
SUPPLY:
Fuse
F 100mA
250V AC
Line
Neutral
230V AC
Supply
Fuse should be connected.
Cable size: 1,5mm²
1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power supply switch shall bring the identification of
the relevant instrument and it should be easily accessible by the operator.
Equipment is protected throughout
by
DOUBLE INSULATION
Holding screw 0.4-0.5Nm.
Line
Neutral
ENDA
EPV742
is intended for installation in control panels. Make sure that the device is
used only for intended purpose.The electrical connections must be carried on by a qualified
staff and must be according to the relevant locally applicable regulations. During an
installation, all of the cables that are connected to the device must be free of electrical
power. The device must be protected against inadmissible humidity, vibrations and severe
soiling. Make sure that the operation temperature is not exceeded. The cables should not
be close to the power cables or components.
CONNECTION DIAGRAM
EPV742-E-01-170330
97mm
2
2
Connection
Cables
Panel
1
1
75mm
8
4
m
m
68 mm
+0.7
6
8
m
m
+
0
.7
Note :
If
1tYp
input type
“
u500
”
is selected, the measurement terminals 13 and 16 of the terminals
must be connected
.
Otherwise, measurement will be incorrect.
If
1tYP
input type “
u100
” or
utrr
is selected, the measurement terminals 14 and 15 of
the terminals must be connected. Otherwise, measurement will be incorrect.
OUT
AC
DC
AC
/