The upper limit of the hysteresis value

Delay time for the upper limit alarm

The lower limit of the setpoint

The lower limit of the hysteresis value

Delay time for the lower limit alarm

Input type selection

Measurement method (

0

=

AC

1

=

DC

2

=

ACDC

)

Decimal point. (0=X, 1=X.X, 2=X.XX, 3=X.XXX)

Baudrate (0=Off;1=1200;2=2400; 3=4800; 4=9600; 5=19200
6= 38400; 7= 57600; 8= 115200)

dlyU

L0Ll

HY5L

dLyl

UPLL

1tYP

typE

dpnt

OPTN

aDr5

BAUD

100

500.0

1,0

1,0

0

no

aCdC

0.0

4

1

 oFF

  Input Register 
      Addresses

Decimal

Hex

Data 
Type

Data Content

Parameter
   Name

Read/Write Permission

0000d

0x0000

word

 Measured voltage value

--

Only Readable

INPUT REGISTERS FOR R EXTENSION DEVICES

  Discrete Input 
      Addresses

Decimal

Hex

Data 
Type

Data Content

Parameter
    Name

 0000d

0x0000

Bit

Relay output state (0=

OFF

; 1=

ON

)

--

DISCRETE INPUTS FOR R EXTENSION DEVICES

  Coil Addresses

Decimal

Hex

Data 
Type

Data Content

Parameter
    Name

 Read/Write 
Permission

 0000d

0x0000

Bit

Alarm output state (0=

no

; 1=

nc

)

0tYP

COILS FOR R EXTENSION DEVICES

Status
Value

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Only Readable

Read/Write Permission

Readable/Writable

0000d

0003d

0004d

0005d

0006d

0007d

0x0000

0x0003

0x0004

0x0005

0x0006

0x0007

word

word

word

word

word

word

Measurement method (

0

=

AC

1

=

DC

2

=

ACDC

)

Decimal point. (0=X.XX,1=X.X,2=X)

Baudrate (0=Off;1=1200;2=2400; 3=4800; 4=9600; 5=19200
6= 38400; 7= 57600; 8= 115200)

typE

dpnt

OPTN

aDr5

BAUD

100

aCdC

0.000

4

1

9600

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

Readable/Writable

*Holding Register Parameter Table (No Relay Models)

Device address for RS485 network connection.
Adjustable between 1-247.

Sampling time of the measurement value. If 1 is selected, it is
250ms. If 2 is selected, it is 500ms. If 3 is selected, it is 750ms.
If 4 is selected, it is 1 second.

Sampling time of the measurement value

Device address for RS485 network connection.
Adjustable between 1-247.

*

 Coil and Discrete input parameters are not available in the devices those have no relay

 

Holding Register 
      Addresses

Decimal

Hex

Data
Type

Data Content

Parameter
    Name

 Read/Write
Permission

Status
Value

0000d

0x0000

word

Voltage Conversion Rate

Readable/Writable

u.t.r.r

HOLDING REGISTERS FOR R EXTENSION DEVICES

ENDA EPV742  DIGITAL VOLTMETER  MODBUS PROTOCOL ADDRESS MAP

0013d

0x000D

word

Readable/Writable

Alarm output status

0tyP

0

Note 1 :

 

0tyP

 menu parameters can be used as “Holding Register” or “Coil.

Note 2 :

 Received "ModBus input register value" is multiplying by 1000 (based on 

d.pnt

) and mV value reached.

For example ;
if modbus value is 2842, (for 

d.pnt

 = 2 (

0.00

))   28.42x1000 = 28420 mV, ie 28.42V

if modbus value is 2842, (for 

d.pnt

 = 3 (

0.000

)) 2.842x1000 = 2842   mV, ie 2.842V

0008d

0x0008

word

Readable/Writable

u.t.r.r

The upper limit of the setpoint

HY5U

0,0

Input type selection

1tYP

Voltage Conversion Rate

u.t.r.r

Readable/Writable

u.t.r.r

0001d

0x0001

word

no

EPV742-E-01-170330

 

4

/4

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

ENDA

TM

Summary of Contents for EPV742

Page 1: ...0 DC voltages 870kΩ 1 4 SİSEL MÜHENDİSLİK ELEKTRONİK SAN VE TİC A Ş Şerifali Mah Y Dudullu 34775 ÜMRANİYE İSTANBUL TURKEY Tel 90 216 499 46 64 Pbx Fax 90 216 365 74 01 url www enda com tr Barbaros Cad No 18 ENDA TM Read this document carefully before using this device The guarantee will be expired by device damages if you don t attend to the directions in the user manual Also we don t accept any c...

Page 2: ...unting clamps Flush mounting clamp Gasket NOTE SUPPLY Fuse F 100mA 250V AC Line Neutral 230V AC Supply Fuse should be connected Cable size 1 5mm 1 Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245 2 In accordance with the safety regulations the power supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator Equ...

Page 3: ... input 14th and 15th terminals u t r r is hiden in the menu If U500 500V input 13th and 16th terminals is selected By using Max u t r r is hiden in the menu If u t r r is selected By using Max 100V input 14th and 15th terminals u t r r value appears in the menu and can be adjusted between 1 and 9999 SET SET u tr r 3 4 Decimal Indicator 0 If device includes relay dPnt type may change according to r...

Page 4: ...t 0 X XX 1 X X 2 X Baudrate 0 Off 1 1200 2 2400 3 4800 4 9600 5 19200 6 38400 7 57600 8 115200 typE dpnt OPTN aDr5 BAUD 100 aCdC 0 000 4 1 9600 Readable Writable Readable Writable Readable Writable Readable Writable Readable Writable Readable Writable Holding Register Parameter Table No Relay Models Device address for RS485 network connection Adjustable between 1 247 Sampling time of the measureme...

Reviews: