       PROGRAMMABLE AC/DC VOLTMETER

ENDA

EPV742

SET

LOCK

0.000

&

PROGRAMMING MODE

EPV742  PROGRAMMING DIAGRAM

LOCK

Lock / Unlock

Keypad

Locks / Unlocks keypad.

Used for displaying and configuring the selected parameter value.

Programming

Key

Used for increasing the setpoint value and changing parameters.
When held down for a few seconds, configured numeric value increases faster.

When held down for a few seconds, configured numeric value increases faster.

Used for decreasing the setpoint value and changing parameters.

Increment

Key

Decrement

Key

SET

If these keys are pressed and held for 3 seconds, “Programming Mode” is entered or it returns to “Running Mode”. If           and          keys are pressed while parameter names are displayed, than it returns to measured value.

SET

SETTING UP THE PARAMETERS

 tYPE

 dC

 

ACdC

If        key is pressed, the current value of the parameter appears by flashing on the display.

SET

After the setting up the parameters, if set key is pressed again, adjusted parameter name appears on display.

By using “UP” or “DOWN” navigation keys,  selected parameter can be adjusted to the desired value.

SET

SET

Measured Value

Measured Value

LOCK

LOCK

L0C

UL0C

0.00

0.00

LOCKING & UNLOCKING KEYPAD

SET

 

UPLL

 LOLL

0.00

0.00

Measured

Value

+

By pressing to 

SET

 key for 3 seconds, quick menu is entered.

QUICK MENU

&

&

01.01

2015

 Year

 Day.Month

If these keys are pressed and held together, revision date appears as day, 
month and year.
While revision information displayed and if one of the pressed key is 
released, measured value is displayed again.

Measured Value

SET

0.00

REVISION NUMBER

Powered on device by pressing       key 

dPAr

 message appears 

on display and device reset to default settings.

Measured current value is higher than maximum scale.

Measured current value is lower than minimum scale.

DEFAULT SETTINGS

ERROR MESSAGES

EPV742-E-01-170330

ConF

Out1

*

*

 tYpE

 d.pnt

 Opnt

 Adr5

 bAUd

 

UPLL

 

HYSU

 

dLYU

 LOLL

 

HYSL

Measurement Method

Can be set as 

AC

DC

 or  

ACdC

 . Adjusted measurement method indicated by top of 

the display LEDs.

Voltage Conversion Rate

Can be adjusted between 

1

 (/100) and 

9999

 (/100).

If parameter is changed, upper limit value set to the upper scale value,
lower limit value set to the lower scale value and  hysteresis values are set to the 0,1.

 OtYp

 

dLyL

*

*

*

*

*

*

i

*

1TYP

Input Type Selection

 

If  

U100

  is selected ; By using Max. 100V input (14th and 15th terminals),  

u.t.r.r.

  

is hiden in the menu. 
If  

U500

  

 500V input (13th and 16th terminals),  

is selected  By using Max.

u.t.r.r.

   

is hiden in the menu.
If 

u.t.r.r.

  is selected ; By using Max. 100V input (14th and 15th terminals), 

u.t.r.r.

 

value appears in the menu and can be adjusted between 1 and 9999.

SET

SET

&

&

 u.tr.r.

 3/4

Decimal Indicator 

0

If device includes relay, 

dPnt

 type may change according to relay 

parameters value.

If  measured value is lower than 10, it can be shown 

as

 (

0.0 0

) , (

0.00

) , (

0.0

) or 

(

0

), (For DC measurements (

0.00

) , (

0.0

) or (

0

) ). 

If 

measured value between 10 and 100

,

 it can be shown as (

0.00

) ,(

0.0

) or (

0

), 

(For DC measurements  (

0.0

) or (

0

) ).

If measured value between 100 and 1000, it can be shown as (

0.0

) or (

0

), (For 

DC measurements only (

0

) .

Samping Time

If 1 ( 

1

 ) is selected ; sampling time of the measurement is 250ms,

If 2 ( 

2

 ) is selected, it is 500ms. If 3 ( 

3

 ) is selected, it is 750ms. 

If 4 ( 

4

 ) is selected, it is 1 second.

Device Address

It can be adjusted between 

1

 - 

247

 .

B

aud

 Rate

It can be adjusted as

 OFF

1200

2400

4800

9600

19200

38400

57600 

and 

115200 .

(*)    
the devices those have no relay.

(**) 

 The 

Adr5

 and 

baud

 parameters are only in the devices those have 

modbus.

There are only 

  parameters in 

 

1tYP. 

u.t.r.r

 , 

tYPE

,

 

d.Pnt

 , 

0ptn

Out1 Output

It can be adjusted as 

n.o.

  or  

 If   

  is selected, incase of 

alarm, out relay is activated.

N.c.

n.o

Upper Limit Value

If 

1typ

 parameter is selected as 

u.t.r.r.

 , can be increased up 

to  

u.t.r.r.

 value. If selected as 

U100

 , can be increased up to 

100 value. If selected as 

U500

 , can be increased up to 500 

value. 
This parameter value can not be less than ( 

l0ll

 - 

HY5.l

 - 

HY5U

 ).

Hysteresis Value for Upper Limit

It can be adjusted between  

and 

20

  value. This parameter 

can’t be higher than (

 

 - 

 - HY5L 

).

If   

c

trr

 parameter is changed,  

HY5U 

gets 

0.1

  value.

Upl1

l0l1

Delay Time for Upper Limit Alarm

It can be adjusted between

 

0

 and

 

900 

seconds .

Lower Limit Value

While in DC measurement type ;
If the 

u.t.r.r.

 parameter is selected, it can be decreased to -999, 

If the 

U100

 parameter is selected, it can be decreased to -100,

If the 

U500

 parameter is selected, it can be decreased to -500.

While in 

AC

 or 

ACDC

 measurement type, it can be decreased to 

minimum 0.
This parameter can be increased up to ( 

UP.L1

 - 

Hy5

 - 

HY5L

 ).

Hysteresis Value for Lower Limit

It can be adjusted between 

and  

20

  . This parameter can’t be 

higher than (

 

 - 

 - 

 

) value. If  

u.t.r.r 

or 

1tYP

  parameter is changed,  

HY5L

  gets   

0.1  

value.

UPLL

L0LL

HY5U

Delay Time for Lower Limit Alarm

 

It can be adjusted between 

0

 and 

900

 seconds.

Includes in R extension devices.

 OUT

   AC

   DC

AC

/

DC

Summary of Contents for EPV742

Page 1: ...0 DC voltages 870kΩ 1 4 SİSEL MÜHENDİSLİK ELEKTRONİK SAN VE TİC A Ş Şerifali Mah Y Dudullu 34775 ÜMRANİYE İSTANBUL TURKEY Tel 90 216 499 46 64 Pbx Fax 90 216 365 74 01 url www enda com tr Barbaros Cad No 18 ENDA TM Read this document carefully before using this device The guarantee will be expired by device damages if you don t attend to the directions in the user manual Also we don t accept any c...

Page 2: ...unting clamps Flush mounting clamp Gasket NOTE SUPPLY Fuse F 100mA 250V AC Line Neutral 230V AC Supply Fuse should be connected Cable size 1 5mm 1 Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245 2 In accordance with the safety regulations the power supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator Equ...

Page 3: ... input 14th and 15th terminals u t r r is hiden in the menu If U500 500V input 13th and 16th terminals is selected By using Max u t r r is hiden in the menu If u t r r is selected By using Max 100V input 14th and 15th terminals u t r r value appears in the menu and can be adjusted between 1 and 9999 SET SET u tr r 3 4 Decimal Indicator 0 If device includes relay dPnt type may change according to r...

Page 4: ...t 0 X XX 1 X X 2 X Baudrate 0 Off 1 1200 2 2400 3 4800 4 9600 5 19200 6 38400 7 57600 8 115200 typE dpnt OPTN aDr5 BAUD 100 aCdC 0 000 4 1 9600 Readable Writable Readable Writable Readable Writable Readable Writable Readable Writable Readable Writable Holding Register Parameter Table No Relay Models Device address for RS485 network connection Adjustable between 1 247 Sampling time of the measureme...

Reviews: