58
Maintenance
Novajet PROe Series Service Manual
There are two basic measurements that are to be made using
this kit (ensure power is off prior to performing these procedures):
1. Slide Shaft Profile Adjustment
2. Carrier (Cartridge) Head Height Setting
1.
Connect the dial gauge micrometer to the Shaft mounting
block as shown in Figure 3-11.
Figure 3-11. Dial Gauge Micrometer Assembly.
2.
Place gauge against left side of shaft assembly allowing
micrometer tip to rest directly on top of shaft. See Figure 3-
12. Zero the gauge (this is to become the reference point).
Figure 3-12. Measurement Positions for Slide Shaft.
3.
Measure the right side (next to media alignment mark.)
and note the difference. Divide this amount by two.