Function parameter schedule graph
24
1: Parameter upload
2: Parameter download 1 (Without motor parameter)
3: Parameter download 2 (With motor parameter)
F01
-
Basic Run Function Parameter Group
Function
code
Name
Set range
Min.
unit
Factory
default
Modifi
-cation
F01.00
Main frequency
input channel
selection
0: Operation keyboard digital setup
1: AI1 analog setup
2: AI2 analog setup
3:Terminal UP/DOWN adjusting setup
4:Communication provide( Communication address:
1E01).
5:EAI1 analog setup.(Effective expansion)
6:EAI2 analog setup. (Effective expansion)
7:High speed pulse setup X8 terminal need choose the
suitable function)
8:Terminal pulse setup(X8 terminal need choose the
suitable function)
9:Terminal encoder setup(X1:X2 connect the encoder
punctuation input)
10
~
14: Reserved
1 0
○
F01.01 Main
frequency
digital setup
0.00Hz
~
upper limit frequency
0.01Hz 50.00Hz
○
F01.02 Main
frequency
digital control
Only when parameter F01.00=0,3,4 valid. Units digit:
power down reserve setup
0:Main frequency power down reserve.
1:Main frequency power down no reserve. Tens digit:
halt reserve setup
0:Halt main frequency hold
1:Halt main frequency recovery F01.01
Hundreds digit: Set of communication presetting
frequency dimension
0:Preset of absolute frequency mode(preset 5000
represent 50.00Hz).
1:Preset 10000 represent upper limit frequency
(F01.11).
1 00
○
F01.03 Auxiliary
frequency input
channel select
0: Operation keyboard digital setup
1: AI1 analog setup
2: AI2 analog setup
3:Terminal UP/DOWN adjusting setup
4:Communication provide (Communication address:
1E01).
5:EAI1 analog setup. (Effective expansion)
6:EAI2 analog setup.(Effective expansion)
7:High speed pulse setup X8 terminal need choose the
suitable function)
8:Terminal pulse setup(X8 terminal need choose the
suitable function)
9:Terminal encoder setup(X3:X4 connect the encoder
punctuation input)
10: Reserved
11: Process PID Setting
12
~
20: Reserved
1 20
○
F01.04 Auxiliary
frequency digital
0.00Hz
~
upper limit frequency
0.01Hz 0.00Hz
○