INSTALLATION INSTRUCTIONS

Locating Wall Opening

The furnace is to be located on an outside wall. Locate wall studs 

so that wall opening will be located between wall studs. The fur-

naces is 14 1/8” (358mm) in width and can be recessed between 

standard 16” (406mm) on center wall stud. The wall opening re-

quired as shown in Figure 5 is a diameter of 7 1/2” (191mm).
A template is provided in furnace carton for positioning furnace 

on the wall. Also, refer to Figure 5 and Figure 7 for positioning 

the furnace on wall and for locating gas line connection.

Installing Optional Side Outlets

Side outlet register, SOR-1 may be installed on one or both sides 

of the furnace at the required clearances of 18” (457mm) to adja-

cent wall or combustible material as shown in Figure 6.

1. Turn “OFF” all electric power to the furnace.

2. Remove the front panel from the furnace.

3. Remove the (2) #8 X 3/8” (9mm) screws that attach the inner 

shield cover plate to the inner shield.

4. Scribe a line between the four dimples on the outer casing 

side to form a square.

5. Drill a pilot hole within the scribed square on the outer casing. 

Remove the sheet metal within the scribed square with a tin 

snips or comparable tool. Attention! Do not cut the electrical 

wires located between the outer casing and the inner shield.

6. Insert the 5” x 5” (127mm x 127mm) inner boot through the 

outer casing. Align the clearance holes on the inner boot with 

the crew holes on the inner shield. Attach inner boot to inner 

shield with (2) #8 x 3/8” (9mm) screws removed in Step 3.

7. Place the register over the 5 1/2” (140mm) square opening 

with the louvers set for the desired direction and mark the 

mounting holes using the register as a template.

8. Drill (2) 1/8” diameter holes in cabinet side and attach the 

register with (2) #10 x 1” (25mm) provided screws.

9. Installation of SOR-1 is completed.

Side outlet kit, SOK-1

, 10” (254mm) boot assembly with reg-

ister, for warm air discharge into an adjoining room may be in-

stalled on either side of the furnace at the required clearance of 4” 

(102mm) to adjacent wall as shown in Figure 6.
To install SOK-1, please use step 1 through 5 in the SOR-1 in-

structions for DVC-35 furnaces. Then, use the following Steps to 

complete the installation of the SOK-1.

1. Using the inner and outer boots as hole templates, mark and 

drill (4) 1/8” (3mm) diameter holes in the inner shield and (4) 

1/8” (3mm) diameter holes in the cabinet side.

2. Locate and cut a 6 3/4” (171mm) square opening through 

wall.

3. Attach furnace to wall (see Attaching Furnace to Wall).

4. With furnace in place, after checking alignment of side outlet 

opening in wall and furnace, place the 9 3/8” x 9 3/8” (238mm 

x (238mm) side outlet wall plate over outer boot, pass the outer 

boot through the wall and attach side wall plate to furnace side 

of wall with (2) #10 x 1 1/2” (38mm) provided screws.

5. Attach outer boot to the cabinet side with (4) #8 x 1/4” (6mm) 

provided screws.

6. Position and attach inner boot to inner shield with (4) #8 x 

1/4” (6mm) provided screws.

7. Place the register over the 6 3/4” (171mm) square opening with 

the louvers positioned for the desired discharge direction and 

mark the mounting holes using the register as a template.

8. Drill (2) 1/8” (3mm) diameter holes in the wall and attach the 

register with (2) #10 x 1 1/2” (38mm) provided screws.

9. Installation of SOK-1 is completed.

4” MINIMUM TO COMBUSTIBLE
WALL OR SURFACE

VENT

TERMINA

L

4” MINIMUM TO COMBUSTIBLE
WALL OR SURFACE

18” MIN. CLEARANCE TO
WALL OR COMBUSTIBLE
SURFACE USING MODEL
SOR-1 SIDE REGISTER

5 ½”

5 ½”

12”

CLEARANCE FOR SIDE OUTLET KITS TO ADJACENT WALL

UNIT CANNOT BE RECESSED
WHEN SIDE REGISTERS ARE
USED.

WHEN SIDE REGISTERS ARE
NOT USED, UNIT MAY BE RECESSED
UP TO 9 1/2”

Figure 5

Figure 6

Summary of Contents for DVC-35

Page 1: ...hich can cause death or serious illness Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other amma ble vapors and liqu...

Page 2: ...11 DVC 35SPP Standing Pilot Lighting Instructions 12 DVC 35IP Intermittent Pilot Lighting Instructions 13 Pilot Flame Characteristics 14 Main Burner Flame Characteristics 15 Wiring 15 16 Service and M...

Page 3: ...quali ed service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that control compartments burners and circulating air passage...

Page 4: ...scaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify i...

Page 5: ...iredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certi ed 3 SIGNAGE Ametalorplasticidenti cationplateshallbe permanently mounted to the exterior...

Page 6: ...i ed agency means any indi vidual rm corporation or company which either in person or through a representative is engaged in and is responsible for a the installation or replacement of gas piping or b...

Page 7: ...aller for installation or relocation Compounds used on threaded joints of gas piping shall be resis tant to the action of lique ed petroleum gases The gas lines must be checked for leaks by the instal...

Page 8: ...4 19mm and maxi mum wall depth is 10 254mm The maximum wall depth may be extended to 19 483mm using the model DV 1190 extended ue kit The use of tubes not supplied by the manu facturer results in unsa...

Page 9: ...in cabinet side and attach the register with 2 10 x 1 25mm provided screws 9 Installation of SOR 1 is completed Side outlet kit SOK 1 10 254mm boot assembly with reg ister for warm air discharge into...

Page 10: ...nace installed on the wall the 6 152mm diameter inlet tube and the 4 102mm diameter ue outlet tube are to be marked and cut using the following procedure 1 Attach 6 152mm diameter air inlet tube onto...

Page 11: ...installed on a uniform outside wall When the wind comes from any angle up down or from either side it must hit the vent cap equally over both the air inlet and the ue outlet portions of the vent Any w...

Page 12: ...er front panel 5 Turn gas control knob clockwise to OFF 6 Wait ten 10 minutes to clear out any gas Then smell for gas including near the oor If you smell gas STOP Follow B in the safety information ab...

Page 13: ...s been under water Immediately call a quali ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRU...

Page 14: ...lights a pilot that in turn lights the main burner The gas valve used in this system is a step opening which opens at a lower pressure for ignition and then steps to a full inlet pressure of 4 H2 O p...

Page 15: ...bsence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 if an external electrical source is utilized This appliance is equipped with three prong grou...

Page 16: ...W PILOT OUTLET WIRING TO 24 V THERMOSAT TO 24 V COMMON ON TRANSFORMER TO 24 V HOT ON TRANSFORMER IGNITOR PILOT ASSY IP MODEL GAS VALVE AND WIRING L2 NEUTRAL L1 HOT 120 VAC MOTOR FAN SWITCH 120VAC 40 V...

Page 17: ...knob for being in the Pilot position 2 Check pilot adjustment for being full open counterclockwise to open 3 If gas is available in the supply tubing the pilot ori ce and or pilot burner is probably...

Page 18: ...Call for Heat Ends Flame Signal Lost Pilot Valve Ignition OFF Wait for Flame Signal to Disappear Pilot Valve Closes Ignition OFF Main Pilot Valves Close Flame Lost More Than 5 Times in One Call for H...

Page 19: ...er Cable Check that Pilot Gas is Flowing Wait to Assure Pilot Gas Tubing is Purged Measure Voltage Between 24V Hot and 24V Common Leads to SmartValve Control Must Measure at Least 19 5 VAC with Ignite...

Page 20: ...DV 1246 MOTOR MOUNTING BRACKET 44 DV 1239 BURNER BRACKET 13 R 1536 BUSHING 45 UH 810 TRANSFORMER MOUNTING BRACKET SPP ONLY 14 R 1499 RUBBER GROMMET 4 REQUIRED 45 UH 452 TRANSFORMER MOUNTING BRACKET I...

Page 21: ...12430 11 1008 Page 21 PARTS VIEW...

Page 22: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: