background image

12430-11-1008

Page 20

HOW TO ORDER REPAIR PARTS

Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts 

through the distributor. Parts can be shipped directly to the service person/dealer.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your 

equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate 

illustration and list. Be sure to give all this information...
Furnace Model Number 

 

Part Description 

Furnace Serial Number 

 

Part Number 

Type of Gas (Propane or Natural) 
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Ship-

ments contingent upon strikes, fires and all causes beyond our control.

Empire Comfort Systems, Inc.

 Nine Eighteen Freeburg Ave. Belleville, IL 62222-0529

PARTS LIST

PLEASE NOTE: 

When ordering parts, it is very important that 

part number

 and 

description

 of part coincide.

INDEX

NO.

PART 

NUMBER

DESCRIPTION

INDEX

NO.

PART

NUMBER

DESCRIPTION

1

DV-1213

TOP PLATE

34

DV-781

OBSERVATION HOLE COVER WITH MICA

2

R-3165

DOOR CLIP (2 REQUIRED)

35

M-155

GASKET - OBS HOLE

3

DV-1204

CASING SIDE - RIGHT

36

FF-160

PIEZO BRACKET (SPP ONLY)

4

DV-1202

CASING BACK

37

DV-1240

BURNER COMPARTMENT FRONT

5

DV-1205

CASING SIDE - LEFT

38

DV-12655

BURNER COMPARTMENT BODY

6

DV-1249

AIR DROP

39

712059

GASKET - TUBE SEAL

7

DV-1230

TURBULATOR (3 REQUIRED)

40

DV-775

SEAL BRACKET (SPP ONLY)

8

DV-1233

OUTLET BOX REAR

40

DV-691

SEAL BRACKET (IP ONLY)

9

DV-1224

OUTLET BOX COVER

41

M-156

MANIFOLD GASKET

10

R-3161

FAN BLADE

42

DV-1235

PILOT BRACKET (IP ONLY)

11

R-3166

FAN MOTOR

43

R-3031

BURNER (3 REQUIRED)

12

DV-1246

MOTOR MOUNTING BRACKET

44

DV-1239

BURNER BRACKET

13

R-1536

BUSHING

45

UH-810

TRANSFORMER MOUNTING BRACKET (SPP ONLY)

14

R-1499

RUBBER GROMMET (4 REQUIRED)

45

UH-452

TRANSFORMER MOUNTING BRACKET (IP ONLY)

15

R-1454

BRASS BUSHING (4 REQUIRED)

46

R-1995

TRANSFORMER (SPP ONLY)

16

R-3164

DOOR CLIP (2 REQUIRED)

46

R-998

TRANSFORMER (IP ONLY)

17

DV-1251

INNER SHIELD - RIGHT (INCLUDES NO. 22)

47

UH-451

JUNCTION BOX COVER

18

R-6176

FAN CONTROL SWITCH

48

DV-572

JUNCTION BOX

19

R-3175

LIMIT SWITCH

49

R-1410

BUSHING

20

DV-1255

INNER SHIELD FRONT (USA)

50

R-690

CORD SET

20

15666

INNER FRONT ASSEMBLY (CANADA)

51

R-1515

BUSHING

21

DV-1253

INNER SHIELD COVER PLATE (2 REQUIRED)

52

DV-1215

BOTTOM PLATE

22

DV-1252

INNER SHIELD - LEFT (INCLUDES NO. 22)

53

R-3034

PILOT - NAT (SPP ONLY)

23

DV-1257

EXCHANGER ASSEMBLY

53

R-3035

PILOT - LPG (SPP ONLY)

24

R-3162

FILTER

54

GWT-021

PILOT BRACKET (SPP ONLY)

25

R-3163

FILTER RETAINER

55

R-3180

ELECTRODE AND WIRE (SPP ONLY)

26

R-3232

PILOT - NAT (IP ONLY)

56

R-2256

THERMOCOUPLE - 18” (SPP ONLY)

26

R-3233

PILOT - LPG (IP ONLY)

57

R-6389

WALL THERMOSTAT - 24 VOLT

27

P-88-61

ORIFICE - NAT (3 REQUIRED)

58

DV-1273

VENT KIT COMPLETE

27

P-88-61C

ORIFICE - LPG (3 REQUIRED)

59

DV-1355

FLUE OUTLET TUBE

28

DV-1236

MANIFOLD

60

DV-1354

AIR INLET TUBE

29

DV-1259

FRONT PANEL

61

DV-131

OUTSIDE MOUNTING PLATE

30

P-112

MANIFOLD UNION

62

DV-769

VENT CAP

31

R-1109

BUSHING (3/8 X 1/2)

NOT SHOWN

DV-1261

PILOT TUBING

31

R-9505

BUSHING (1/2 X 3/4) - NAT (IP ONLY)

NOT SHOWN

R-1081

PILOT ORIFICE - NAT (SPP ONLY)

32

R-3170

GAS VALVE - NAT (IP ONLY)

NOT SHOWN

R-1089

PILOT ORIFICE - LPG (SPP ONLY)

32

R-3171

GAS VALVE - LPG (IP ONLY)

NOT SHOWN

R-1233

PILOT ORIFICE - NAT (IP ONLY)

32

R-2148

GAS VALVE - NAT (SSP ONLY)

NOT SHOWN

R-3265

PILOT ORIFICE - LPG (IP ONLY)

32

R-5655

GAS VALVE - LPG (SPP ONLY)

NOT SHOWN

R-3172

WIRE HARNESS (SPP ONLY)

33

R-2708

PIEZO IGNITOR (SPP ONLY)

NOT SHOWN

R-3173

WIRE HARNESS (IP ONLY)

NOT SHOWN

R-3236

WIRE (IP ONLY)

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

Summary of Contents for DVC-35

Page 1: ...hich can cause death or serious illness Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other amma ble vapors and liqu...

Page 2: ...11 DVC 35SPP Standing Pilot Lighting Instructions 12 DVC 35IP Intermittent Pilot Lighting Instructions 13 Pilot Flame Characteristics 14 Main Burner Flame Characteristics 15 Wiring 15 16 Service and M...

Page 3: ...quali ed service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that control compartments burners and circulating air passage...

Page 4: ...scaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify i...

Page 5: ...iredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certi ed 3 SIGNAGE Ametalorplasticidenti cationplateshallbe permanently mounted to the exterior...

Page 6: ...i ed agency means any indi vidual rm corporation or company which either in person or through a representative is engaged in and is responsible for a the installation or replacement of gas piping or b...

Page 7: ...aller for installation or relocation Compounds used on threaded joints of gas piping shall be resis tant to the action of lique ed petroleum gases The gas lines must be checked for leaks by the instal...

Page 8: ...4 19mm and maxi mum wall depth is 10 254mm The maximum wall depth may be extended to 19 483mm using the model DV 1190 extended ue kit The use of tubes not supplied by the manu facturer results in unsa...

Page 9: ...in cabinet side and attach the register with 2 10 x 1 25mm provided screws 9 Installation of SOR 1 is completed Side outlet kit SOK 1 10 254mm boot assembly with reg ister for warm air discharge into...

Page 10: ...nace installed on the wall the 6 152mm diameter inlet tube and the 4 102mm diameter ue outlet tube are to be marked and cut using the following procedure 1 Attach 6 152mm diameter air inlet tube onto...

Page 11: ...installed on a uniform outside wall When the wind comes from any angle up down or from either side it must hit the vent cap equally over both the air inlet and the ue outlet portions of the vent Any w...

Page 12: ...er front panel 5 Turn gas control knob clockwise to OFF 6 Wait ten 10 minutes to clear out any gas Then smell for gas including near the oor If you smell gas STOP Follow B in the safety information ab...

Page 13: ...s been under water Immediately call a quali ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRU...

Page 14: ...lights a pilot that in turn lights the main burner The gas valve used in this system is a step opening which opens at a lower pressure for ignition and then steps to a full inlet pressure of 4 H2 O p...

Page 15: ...bsence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 if an external electrical source is utilized This appliance is equipped with three prong grou...

Page 16: ...W PILOT OUTLET WIRING TO 24 V THERMOSAT TO 24 V COMMON ON TRANSFORMER TO 24 V HOT ON TRANSFORMER IGNITOR PILOT ASSY IP MODEL GAS VALVE AND WIRING L2 NEUTRAL L1 HOT 120 VAC MOTOR FAN SWITCH 120VAC 40 V...

Page 17: ...knob for being in the Pilot position 2 Check pilot adjustment for being full open counterclockwise to open 3 If gas is available in the supply tubing the pilot ori ce and or pilot burner is probably...

Page 18: ...Call for Heat Ends Flame Signal Lost Pilot Valve Ignition OFF Wait for Flame Signal to Disappear Pilot Valve Closes Ignition OFF Main Pilot Valves Close Flame Lost More Than 5 Times in One Call for H...

Page 19: ...er Cable Check that Pilot Gas is Flowing Wait to Assure Pilot Gas Tubing is Purged Measure Voltage Between 24V Hot and 24V Common Leads to SmartValve Control Must Measure at Least 19 5 VAC with Ignite...

Page 20: ...DV 1246 MOTOR MOUNTING BRACKET 44 DV 1239 BURNER BRACKET 13 R 1536 BUSHING 45 UH 810 TRANSFORMER MOUNTING BRACKET SPP ONLY 14 R 1499 RUBBER GROMMET 4 REQUIRED 45 UH 452 TRANSFORMER MOUNTING BRACKET I...

Page 21: ...12430 11 1008 Page 21 PARTS VIEW...

Page 22: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: