Warning:  Conversion must be done by a qualified service technician.  Main burner orifice(s) and new gas 
conversion label are provided in conversion kit attached to manifold pipe.

1.  Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit.
2.  Open brass union located between the gas valve and burner box.  Re-

move the 4 mounting screws securing manifold plate to the burner box.  
Remove the top 2 screws holding the burner box top in place and then 
remove the 1 screw holding the end of the manifold pipe in place.  Grasp 
union and remove manifold pipe.

3.  Remove (1) Natural  gas main burner orifice marked 44 for DV-20E, (2) 

Natural gas main burner orifices marked 44 for DV-40E or (3) Natural 
gas main burner orifices marked 47 for DV-55E located in the manifold 
pipe  and  replace  with  (1)  LP  gas  main  burner  orifice  marked  55  for 
DV-20E, (2) LP gas main burner orifices marked 55 for DV-40E or (3) 
LP gas main burner orifices marked 1.20mm for DV-55E supplied in 
conversion kit.

4.  Replace manifold pipe being sure to locate orifice(s) in the end of the burner.  Secure the manifold and top burner box cover in 

place using the screws earlier removed.  Reconnect the brass union.

5.  Remove the vinyl cap and unscrew the gas control convertible regulator and reverse to LP gas side (red ring on regulator) and screw 

back into place.  Reattach vinyl cap.  Refer to figure illustrating the gas valve.

6.  Place Natural gas main burner orifice(s) in conversion kit.  Attach conversion kit to manifold pipe.  Attach new label to unit name-

plate indicating that the unit was converted to LP gas.

7.  Turn on gas supply to furnace and check all gas connections for leaks with soap solution, watching for bubbles on all gas connec-

tions.

8.  Turn on electrical power to unit and turn on furnace to verify proper operation.  It may take several tries for ignition to completely 

purge all the air from the gas line. 

Warning:  Conversion must be done by a qualified service technician.  Main burner orifice(s) and new 
gas conversion label are provided in conversion kit attached to manifold pipe.

1.  Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit.
2.  Open  brass  union  located  between  the  gas  valve  and  burner  box.  

Remove the 4 mounting screws securing manifold plate to the burner 
box.  Remove the top 2 screws holding the burner box top in place 
and then remove the 1 screw holding the end of the manifold pipe in 
place.  Grasp union and remove manifold pipe.

3.  Remove (1) LP gas main burner orifice marked 55 for DV-20E,  (2) 

LP gas main burner orifices marked 55 for DV-40E or (3) LP gas main 
burner orifices marked 1.20mm for DV-55E located in the manifold 
pipe and replace with (1) Natural gas main burner orifice marked 44 
for DV-20E, (2) Natural gas main burner orifices marked 44 for DV-
40E or (3) Natural gas main burner orifices marked 47 for DV-55E 
supplied in conversion kit.

4.  Replace manifold pipe being sure to locate orifice(s) in the end of the burner.  Secure the manifold and top burner box cover in 

place using the screws earlier removed.  Reconnect the brass union.

5.  Remove the vinyl cap and unscrew the gas control convertible regulator and reverse to Natural gas side and screw back into place.  

The red LP ring will be up just under the vinyl cap.  Reattach vinyl cap.  Refer to figure illustrating the gas valve.

6.  Place LP gas main burner orifice(s) in conversion kit.  Attach conversion kit to manifold pipe.  Attach new label to unit nameplate 

indicating that the unit was converted to Natural gas.

7.  Turn on gas supply to furnace and check all gas connections for leaks with soap solution, watching for bubbles on all gas connec-

tions.

8.  Turn on electrical power to unit and turn on furnace to verify proper operation.  It may take several tries for ignition to completely 

purge all the air from the gas line. 

CONVERSION INSTRUCTIONS FROM (LP) PROPANE GAS TO NATURAL GAS

CONVERSION INSTRUCTIONS FROM NATURAL GAS TO (LP) PROPANE GAS

 

   

   

  

 

 

  

   

   

  

  

GAS VALVE-NATURAL

 

   

   

  

 

 

  

   

   

  

  

GAS VALVE-LP

GAS CONVERSION INSTRUCTIONS

 ACF Greenhouses 

Summary of Contents for DV-55E

Page 1: ...his appliance is only for use with the type s of gas indicated on the rating plate A conver sion kit is supplied with the appliance Installer Leave this manual with the appli ance Consumer Retain this...

Page 2: ...assachusetts 5 Introduction 6 Specifications 6 Gas Supply 7 Gas Conversion Instructions 8 Clearances 9 Furnace Installation 9 11 Lighting Instructions 12 Wiring 13 Maintenance 14 Operation and Trouble...

Page 3: ...nstallation and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected beforeuseandatleastannuallybyaqualifiedserviceperson More frequent cleaning may be required due to...

Page 4: ...ights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption...

Page 5: ...naccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshall be permanently mounted to the exterior o...

Page 6: ...be performed only by a qualified agency The term qualified agency meansanyindividual firm corporationorcompanywhicheitherin person or through a representative is engaged in and is responsible for a th...

Page 7: ...ontrol valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the g...

Page 8: ...ning Conversion must be done by a qualified service technician Main burner orifice s and new gas conversion label are provided in conversion kit attached to manifold pipe 1 Make sure gas supply to fur...

Page 9: ...NG The nearest point of the vent cap should be a minimum horizontal distant of six 6 feet 1 83m from any pressure regulator In case of regulator malfunction the six 6 feet 1 83m distance will reduce t...

Page 10: ...if plastic anchors are used Attach the two wall mounting brackets to the casing back by using 4 10 x 1 2 13mm hex head screws provided Figure 5 Figure 6 Figure 7 Figure 8 2 51mm TO 13 330mm 2 51mm TO...

Page 11: ...ach the right shroud and left shroud to the casing back the 3 4 wide flange on the shroud must be positioned toward the casing side When positioned correctly the 6 louvers on the shroud will be facing...

Page 12: ...lified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 STOP Read the safety information above 2 Set the therm...

Page 13: ...VAC circuit If current is below 1 micro amp remove sensor clean with light sandpaper and retest Note This heater is equipped with a remote bulb electronic thermistor control located down low at the ba...

Page 14: ...lve 4 Remove gas valve from gas valve bracket Removing Main Burner Orifice s 1 Remove front grill assembly 2 Remove burner compartment access panel 2 screws 3 Disconnect manifold union assembly 4 Disc...

Page 15: ...terminal on the board The inducer blower circuit is energized and the inducer blower comes on for 15 seconds pre purging out any gas and closing the pressure switch The hot surface ignitor is energize...

Page 16: ...essure switch is closed with inducer off Check Pressure Switch and Replace 4 Flashes Lockout due to failed ignition Check for Broken Ignitor Check for Bent Ignitor Bracket Ignitor too far from Burner...

Page 17: ...e Description of each part from the following appropriate illustration and list Be sure to give all this information Furnace Model Number Part Description Furnace Serial Number Part Number Type of Gas...

Page 18: ...19563 3 0907 Page 18 PARTS VIEW ACF Greenhouses...

Page 19: ...19563 3 0907 Page 19 SERVICE NOTES ACF Greenhouses...

Page 20: ...3 0907 Page 20 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com ACF Greenh...

Reviews: