background image

19563-3-0907

Page 17

INDEX 

PART

  NO. 

NUMBER 

DESCRIPTION

INDEX 

PART

  NO. 

NUMBER 

DESCRIPTION

 

DV-1378 

SHROUD TOP

 

DV-1376 

SHROUD SIDE RIGHT

 

R-2521 

AIR FILTER

 

DV-1375 

FILTER RETAINER

 

DV-1379 

WALL MOUNTING BRACKET

 

DV-1048 

WALL BRACKET - 2 REQ

 

R-2586 

CONTROL DOOR PIN - 2 REQ

 

19676 

CONTROL DOOR ASSEMBLY

 

DV-1373 

CASING TOP

 

10 

R-2661 

BLOWER HOUSING - 2 
REQUIRED

 

11 

R-2663 

BLOWER WHEEL - 2 REQ

 

12 

R-2662 

BLOWER MOTOR

 

13 

R-2598 

MOTOR BASE WASHER - 4 REQ

 

14 

R-1279 

LIMIT SWITCH

 

15 

DV-1367 

INNER TOP

 

16 

R-2546 

CONTROL KNOB

 

17 

R-2522 

ON/OFF SWITCH

 

18 

19561 

JUNCTION BOX

 

19 

DV-1370 

JUNCTION BOX COVER

 

20 

R-1995 

TRANSFORMER

 

21 

R-6988 

PRESSURE SWITCH

 

22 

R-8140 

CONTROL BOARD

 

23 

R-2577A 

TEMPERATURE CONTROL 
BOARD

 

24 

DV-1365 

CASING WELDED ASSEMBLY

 

25 

R-1468 

STRAIN RELIEF BUSHING

 

26 

R-2099 

CORD SET

 

27 

DV-1371 

INNER END

 

28 

DV-1372 

CASING SIDE - 2 REQUIRED

 

29 

DV-1163 

COLLECTOR BOX

 

30 

R-2519 

INDUCER WHEEL

 

31 

DV-1169 

INDUCER BLOWER HOUSING 
ASSEMBLY

 

32 

R-2523 

INDUCER MOTOR

Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through 
the distributor. Parts can be shipped directly to the service person/dealer.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your 
equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate 
illustration and list. Be sure to give all this information.

Furnace Model Number 

    Part Description 

Furnace Serial Number  

 

Part Number 

Type of Gas (Propane or Natural) 

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 

Shipments contingent upon strikes, fires and all causes beyond our control.

Empire Comfort Systems, Inc.  Nine Eighteen Freeburg Ave.   Belleville, IL  62222-0529

PLEASE NOTE:  When ordering parts, it is very important that part number and description of part coincide.

 

33 

15785 

EXCHANGER ASSEMBLY

 

34 

19565 

IGNITOR KIT

 

37 

R-2543 

FLAME SENSOR

 

38 

R-2541 

BURNER - 3 REQ

 

39 

R-2575 

FLAME ROLLOUT SWITCH

 

40 

DV-1038 

BURNER COMPARTMENT 
ACCESS PANEL

 

41 

DV-1143 

BURNER COMPARTMENT

 

42 

R-3237 

GAS VALVE - NAT

 

42 

R-3238 

GAS VALVE - LP

 

43 

DV-1366 

VALVE BRACKET

 

44 

DV-1147 

MANIFOLD ASSEMBLY

 

45 

P-88-1.20MM 

ORIFICE (LPG GAS) - 3 REQ

 

45 

P-88-47 

ORIFICE (NAT GAS) - 3 REQ

 

46 

M-148 

MANIFOLD GASKET

 

47 

DV-781 

OBSERVATION HOLE COVER 
ASSEMBLY

 

48 

M-155 

OBSERVATION HOLE COVER 
GASKET

 

49 

15792 

FRONT SHIELD ASSEMBLY

 

50 

DV-1024 

BOTTOM SHIELD

 

51 

DV-1364 

FRONT GRILL ASSEMBLY

 

52 

DV-1380 

CASING FRONT ASSEMBLY

 

53 

R-2539 

HOSE CLAMP - 4 REQ

 

54 

R-3113 

INLET HOSE

 

55 

R-3111 

OUTLET ELBOW

 

56 

DV-1192 

VENT PAN ASSEMBLY

 

57 

R-3114 

INLET CAP

 

58 

R-3115 

WALL PLATE GASKET - INSIDE

 

59 

R-2587 

WALL PLATE GASKET - OUTSIDE 

 

60 

DV-1195 

WALL PLATE - OUTSIDE

 

61 

DV-1193 

TUBE SPACER

 

62 

DV-1194 

END CAP ASSEMBLY

 

63 

DV-1377 

SHROUD SIDE LEFT

  NS 

R-8142 

WIRE ASSEMBLY - CONTROL 
BOARD

HOW TO ORDER REPAIR PARTS

PARTS LIST

 ACF Greenhouses 

Summary of Contents for DV-55E

Page 1: ...his appliance is only for use with the type s of gas indicated on the rating plate A conver sion kit is supplied with the appliance Installer Leave this manual with the appli ance Consumer Retain this...

Page 2: ...assachusetts 5 Introduction 6 Specifications 6 Gas Supply 7 Gas Conversion Instructions 8 Clearances 9 Furnace Installation 9 11 Lighting Instructions 12 Wiring 13 Maintenance 14 Operation and Trouble...

Page 3: ...nstallation and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected beforeuseandatleastannuallybyaqualifiedserviceperson More frequent cleaning may be required due to...

Page 4: ...ights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption...

Page 5: ...naccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshall be permanently mounted to the exterior o...

Page 6: ...be performed only by a qualified agency The term qualified agency meansanyindividual firm corporationorcompanywhicheitherin person or through a representative is engaged in and is responsible for a th...

Page 7: ...ontrol valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the g...

Page 8: ...ning Conversion must be done by a qualified service technician Main burner orifice s and new gas conversion label are provided in conversion kit attached to manifold pipe 1 Make sure gas supply to fur...

Page 9: ...NG The nearest point of the vent cap should be a minimum horizontal distant of six 6 feet 1 83m from any pressure regulator In case of regulator malfunction the six 6 feet 1 83m distance will reduce t...

Page 10: ...if plastic anchors are used Attach the two wall mounting brackets to the casing back by using 4 10 x 1 2 13mm hex head screws provided Figure 5 Figure 6 Figure 7 Figure 8 2 51mm TO 13 330mm 2 51mm TO...

Page 11: ...ach the right shroud and left shroud to the casing back the 3 4 wide flange on the shroud must be positioned toward the casing side When positioned correctly the 6 louvers on the shroud will be facing...

Page 12: ...lified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 STOP Read the safety information above 2 Set the therm...

Page 13: ...VAC circuit If current is below 1 micro amp remove sensor clean with light sandpaper and retest Note This heater is equipped with a remote bulb electronic thermistor control located down low at the ba...

Page 14: ...lve 4 Remove gas valve from gas valve bracket Removing Main Burner Orifice s 1 Remove front grill assembly 2 Remove burner compartment access panel 2 screws 3 Disconnect manifold union assembly 4 Disc...

Page 15: ...terminal on the board The inducer blower circuit is energized and the inducer blower comes on for 15 seconds pre purging out any gas and closing the pressure switch The hot surface ignitor is energize...

Page 16: ...essure switch is closed with inducer off Check Pressure Switch and Replace 4 Flashes Lockout due to failed ignition Check for Broken Ignitor Check for Bent Ignitor Bracket Ignitor too far from Burner...

Page 17: ...e Description of each part from the following appropriate illustration and list Be sure to give all this information Furnace Model Number Part Description Furnace Serial Number Part Number Type of Gas...

Page 18: ...19563 3 0907 Page 18 PARTS VIEW ACF Greenhouses...

Page 19: ...19563 3 0907 Page 19 SERVICE NOTES ACF Greenhouses...

Page 20: ...3 0907 Page 20 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com ACF Greenh...