REqUIREMENTS FOR MASSACHUSETTS

For all side wall horizontally vented gas fueled equipment 

installed  in  every  dwelling,  building  or  structure  used  in 

whole  or  in  part  for  residential  purposes,  including  those 

owned  or  operated  by  the  Commonwealth  and  where  the 

side wall exhaust vent termination is less than seven (7) feet 

above finished grade in the area of the venting, including but 

not limited to decks and porches, the following requirements 

shall be satisfied:

1.  INSTaLLaTION OF CaRBON MONOXIDe DeTeC-

TORS. at the time of installation of the side wall horizontal 

vented gas fueled equipment, the installing plumber or 

gasfitter shall observe that a hard wired carbon monoxide 

detector with an alarm and battery back-up is installed on 

the floor level where the gas equipment is to be installed. 

In addition, the installing plumber or gasfitter shall observe 

that a battery operated or hard wired carbon monoxide 

detector with an alarm is installed on each additional 

level  of  the  dwelling,  building  or  structure  served  by 

the side wall horizontal vented gas fueled equipment. It 

shall be the responsibility of the property owner to secure 

the services of qualified licensed professionals for the 

installation of hard wired carbon monoxide detectors

 

a.  In the event that the side wall horizontally vented gas 

fueled equipment is installed in a crawl space or an 

attic, the hard wired carbon monoxide detector with 

alarm and battery back-up may be installed on the 

next adjacent floor level.

 

b.  In the event that the requirements of this subdivision 

can not be met at the time of completion of installa-

tion, the owner shall have a period of thirty (30) days 

to comply with the above requirements; provided, 

however, that during said thirty (30) day period, a 

battery operated carbon monoxide detector with an 

alarm shall be installed.

2.  aPPROVeD  CaRBON  MONOXIDe  DeTeCTORS. 

each carbon monoxide detector as required in accordance 

with the above provisions shall comply with NFPa 720 

and be ANSI/UL 2034 listed and IAS certified. 

3.  SIGNAGE. A metal or plastic identification plate shall be 

permanently mounted to the exterior of the building at a 

minimum height of eight (8) feet above grade directly in 

line with the exhaust vent terminal for the horizontally 

vented gas fueled heating appliance or equipment. The 

sign shall read, in print size no less than one-half (1/2) 

inch in size, 

“GAS VEnt DIRECtLY BELoW. KEEP 

CLEAR OF ALL OBSTRUCTIONS”.

4.  INSPeCTION. The state or local gas inspector of the 

side wall horizontally vented gas fueled equipment shall 

not approve the installation unless, upon inspection, the 

inspector observes carbon monoxide detectors and signage 

installed in accordance with the provisions of 248 CMR 

5.08(2)(a) 1 through 4.

 

(b)  EXEMPTIONS: The following equipment is exempt 

from 248 CMR 5.08(2)(a)1 through 4: 

 

 

1.  The  equipment  listed  in  Chapter  10  entitled 

“equipment Not Required To Be Vented” in the 

most current edition of NFPa 54 as adopted by 

the Board; and 

 

 

2.  Product approved side wall horizontally vented 

gas  fueled  equipment  installed  in  a  room  or 

structure separate from the dwelling, building or 

structure used in whole or in part for residential 

purposes. 

 

(c)  MANUFACTURER  REQUIREMENTS  -  GAS 

EQUIPMENT VENTING SYSTEM PROVIDED. 

When the manufacturer of Product approved side 

wall horizontally vented gas equipment provides a 

venting system design or venting system components 

with the equipment, the instructions provided by the 

manufacturer for installation of the equipment and 

the venting system shall include:

 

 

1.  Detailed instructions for the installation of the 

venting  system  design  or  the  venting  system 

components; and

 

 

2.  a complete parts list for the venting system design 

or venting system. 

 

(e)  A copy of all installation instructions for all Product 

approved side wall horizontally vented gas fueled 

equipment, all venting instructions, all parts lists for 

venting instructions, and/or all venting design instruc-

tions shall remain with the appliance or equipment 

at the completion of the installation. 

Summary of Contents for DV-25T-1

Page 1: ...ual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO...

Page 2: ...tion 6 Specifications 6 Gas Supply 7 Clearances 8 Installation Instructions 8 10 Thermostat Location 11 Lighting Instructions 12 Pilot Flame Characteristics 13 Main Burner Flame Characteristics 13 Mai...

Page 3: ...o examine venting system periodically and replace damaged parts Do make a periodic visual check of pilot and burner Clean and replace damaged parts CAUTION Pilot hole cover must be kept tightly closed...

Page 4: ...perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wal...

Page 5: ...requiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshallbe permanently mounted to the ex...

Page 6: ...acementofgaspiping gasutilizationequipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency The term qualified agency meansanyindividual firm corporat...

Page 7: ...gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of pipe...

Page 8: ...intake shall be located at least 12 305mm above grade Warning The nearest point of the vent cap should be a minimum horizontal distant of six 6 1 83m feet from any pressure regulator In case of regul...

Page 9: ...ttaching Furnace to Wall Mounting Bracket 1 Remove casing front from furnace 2 Lay furnace face down on a non abrasive work surface 3 Place collar on four inch flue tube against combustion camber back...

Page 10: ...unt ing plate with three 3 10 x 1 2 screws 4 Reassembly and resealing vent air intake system is completed Installing a Vent Near a Window Ledge Other Type of Project or on Siding vinyl aluminum etc Di...

Page 11: ...terminals 400 450 millivolts with thermostat OFF Across the thermopile terminals 150 250 millivolts with thermostat ON Across the thermostat wires at the valve less than 30 millivolts with thermostat...

Page 12: ...ock wise to OFF Do not force 5 Replace casing front assembly 1 Stop Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance if appli cab...

Page 13: ...on the inner casing bottom On Propane gas if a whistling noise resonation occurs screw air adjustment bolt into the chamber support in order to reduce the amount of primary air If the whistling noise...

Page 14: ...occurs a See Page 13 Primary Air Adjustment b Reduce manifold pressure c Size main burner orifice with a drill bit For DV 25 use 54 drill bit For DV 35 use 50 drill bit Removing Main Burner 1 Disconne...

Page 15: ...udes 5 6 26 DV 778 Gasket Burner Door 5 M 178 Gasket Inlet Collar 27 M 151 B Gasket Pilot Burner 6 13106 Inlet Tube inner Welded Assembly 28 DV 994 Pilot Shield 7 13064 Inlet Tube Outer Assembly 29 R...

Page 16: ...13117 10 0709 Page 16 PARTS VIEW...

Page 17: ...the blower assembly The switch box is adjacent to the combustion chamber The fan control is a non adjustableautomatictype Thefancontrolwillrequirebetween 5 and 10 minutes of main burner operation befo...

Page 18: ...ting season using 2 or 3 drops each time If the motor fails to start and hums it could be a tight bearing due to lack of oil This may be corrected by pouring kerosene in the oil holes allowing to stan...

Page 19: ...13117 10 0709 Page 19 SERVICE NOTES...

Page 20: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: