24117-0-0508
Page 8
Locating Firebox
Place firebox in framed opening. Attach the framing brackets to
the firebox and secure firebox to framing. Different hole locations
can be used for finishing materials with thicknesses of 3/8", 1/2"
and 3/4". Secure the brackets with screws provided using two (2)
per framing bracket.
See Figure 7.
Framing brackets should fit directly against framing material. Use
at least one (1) nail or screw per bracket to secure in place.
IMPORTANT!
Check squareness of the firebox prior to securing
to framed opening.
See Figure 8.
Figure 7
Black hoods are furnished with each firebox (or the optional
hood(s)) and MUST be installed before the firebox is used. Failure
to do so may create a possible fire hazard. For shipping purposes,
the hoods are located behind the upper louver(s), or inside the
firebox on flush face units. If brass, stainless steel, or hammered
pewter hoods are desired, they can be purchased as an option.
Attachment is the same as the standard black hood.
Louvered Models
1. Remove upper louver, or flush panel.
2. Place the top hood flange on top of the inner firebox top, then
install three screws through the firebox top from below and
screw into the pilot holes in the hood flange (B).
3. Install one (1) screw at each end of the hood as shown (C).
4. Re-install louver(s) or flush panel(s).
Caution:
All hoods must be installed prior to operation of
appliance.
See Figure 9.
Figure 9
FIREBOX OPENING
CHECK TO SEE
THAT BOX IS SQUARE
PRIOR TO ATTACHING TO
FRAMING
Figure 8
FIREBOX INSTALLATION INSTRUCTIONS (continued)
INSTALLING HOOD
B
C
INNER FIREBOX TOP
Louvered Models
ATTACH (4)
FRAMING BRACKETS
TO SIDE(S) OF FIREBOX
PRIOR TO INSTALLING
UNIT TO FRAMED OPENING