background image

24117-0-0508

Page 14

PARTS LIST

Use Only Manufacturer’s Replacement Parts. Use of Any Other Parts Could Cause Injury Or Death.

Index 

Number

Part Number

Description

VFP36SB2EL

VFP36SB2EF

VFP36PB2EL

VFP36PB2EF

1

-

-

-

-

FIREBOX ASSEMBLY

2

17149

17149

17149

17149

TOP STANDOFF

3

R9655

R9655

R9655

R9655

INSULATION - TOP

4

24067

24067

24067

24067

INSULATION SUPPORT

5

R7052

R7052

R7052

R7052

SCREEN ROD

6

-

-

R9633

R9633

SCREEN ROD

7

R9631

R9631

R9631

R9631

BRICK PANEL - SIDE BULK

8

19945

19945

19945

19945

BRICK LINER BRACKET

9

20145

20145

20145

20145

HOOD

10

-

-

24056

24056

PENINSULA HOOD

11

20073

20073

20073

20073

INNER AIR BAFFLE

12

18807

18807

18807

18807

LOUVER ASSEMBLY - UPPER

13

18808

18808

18808

18808

LOUVER ASSEMBLY - LOWER

14

-

-

24059

24059

UPPER LOUVER ASSEMBLY

15

-

-

24058

24058

LOWER LOUVER ASSEMBLY

16

19990

19990

19990

19990

BLOWER COVER PLATE

17

23004

23004

23004

23004

HEARTH RETAINER

18

R9293

R9293

R9293

R9293

HEARTH LEDGE - LEFT

19

R9295

R9295

R9295

R9295

HEARTH LEDGE - CENTER

20

R9292

R9292

R9292

R9292

HEARTH LEDGE - RIGHT

21

-

-

R9634

R9634

HEARTH LEDGE

22

10554

10554

10554

10554

NAILING FLANGE

23

-

24051

-

24051

FLUSH PANEL - UPPER - LONG

24

-

24052

-

24052

FLUSH PANEL - LOWER - LONG

25

-

-

-

24054

FLUSH PANEL - UPPER - SHORT

26

-

-

-

24053

FLUSH PANEL - LOWER - SHORT

27

19401

19401

19401

19401

BRICK LINER BRACKET - LOWER

See Page 15 for See-Through Models VFP36SB2E(L,F) Parts View for ordering parts.

See Page 16 for Peninsula Models VFP36PB2E(L,F) Parts View for ordering parts.

Summary of Contents for VFP36PB2EF-1

Page 1: ...y or the gas supplier Carefully review the instructions supplied with the decora tive type unvented room heater for the minimum replace size requirement DO NOT INSTALL A VENT FREE LOG SET IN THIS FIRE...

Page 2: ...ection 9 Wiring Instructions for Installing a Dual Switch Receptacle 10 LK2 Accent Light Accessory 10 Optional Single Speed Blower Installation Instructions 11 13 Maintenance 13 Parts List 14 See Thro...

Page 3: ...val of such component part or accessory Any such action may create a possible re hazard Consult your local building codes Firebox Screen The rebox screen must be in place when the rebox is operating I...

Page 4: ...top standoff screws on the front edge of the top outer wrap See Figures 2a and 2b CLEARANCES FIREBOX STAND OFF COMBUSTIBLE FINISHED WALL OR MANTEL 2 X 4 HEADER TOP OUTER WRAP FINISH WITH TRIM KIT OR N...

Page 5: ...ALLOWED 22 8 20 6 18 5 16 3 14 2 24 0 FIREBOX FACE EXTENDED HOOD VB4H SERIES NOT AVAILABLE ON PENINSULA OPEN END 3 8 COMBUSTIBLE CLEARANCE REQUIRED FROM TOP EDGE OF FIREBOX CLEARANCES Ceiling Clearanc...

Page 6: ...dealer for assistance with this planning Planning Your Installation Accessory kits such as the FBB5 Blower kit Trim kits Mantles plus other Decorative Frame Hood and Door accessory kits may be install...

Page 7: ...D 25 1 2 25 1 2 25 1 2 25 1 2 E 36 36 36 36 F 34 1 4 35 1 4 34 1 4 35 1 4 G 29 1 8 29 1 8 29 1 8 29 1 8 H 41 1 8 41 1 8 41 1 8 41 1 8 I 1 1 4 1 1 4 1 1 4 1 1 4 J 6 1 8 6 1 8 6 1 8 6 1 8 K 8 1 2 8 1 2...

Page 8: ...rposes the hoods are located behind the upper louver s or inside the rebox on ush face units If brass stainless steel or hammered pewter hoods are desired they can be purchased as an option Attachment...

Page 9: ...w c This is in addition to the regulator tted to the log set WARNING CONNECTION DIRECTLY TO AN UNREGULATED L P TANK CAN CAUSE EXPLOSION Install only a ANSI Z21 11 2 vent free log set into this rebox...

Page 10: ...3 wire conductor with ground is recommended however 2 two wire conductors with grounds may be used in place of a 3 wire conductor with a ground if the black wires from the Accent Light and blower acc...

Page 11: ...If installed turn OFF gas supply to rebox gas log 2 If applicable turn OFF electric supply to rebox CAUTION ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LO...

Page 12: ...mbly and retain wires together near the blower motor using the plastic purse clip provided 11 To complete the installation plug the power cord into the junction box receptacle previously installed in...

Page 13: ...ROL SWITCH 1 2 A B 110 VOLT AC JUNCTION BOX WHITE FAN SWITCH BLACK FAN MOTOR ASSEMBLY Figure 18 Figure 19 Keep the control compartment logs and burner area surrounding the logs clean by vacuuming or b...

Page 14: ...8807 18807 18807 18807 LOUVER ASSEMBLY UPPER 13 18808 18808 18808 18808 LOUVER ASSEMBLY LOWER 14 24059 24059 UPPER LOUVER ASSEMBLY 15 24058 24058 LOWER LOUVER ASSEMBLY 16 19990 19990 19990 19990 BLOWE...

Page 15: ...24117 0 0508 Page 15 SEE THROUGH FIREBOX PARTS VIEW 1 2 3 4 5 8 7 8 9 11 12 13 16 17 18 19 20 22 7 24 23 27 23 12 13 9 11 24 20 19 18 27 17 3 4...

Page 16: ...24117 0 0508 Page 16 PENINSULA FIREBOX PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 25 26 23 24 27 12 23 24 13 9 11 3 4 20 19 18 17...

Page 17: ...ewter For use with See Through models VFP36SB2E L F ONLY Contact dealer for all available optional frame kits Bottom Trim Strip Available as optional kits in Black Brass Ham mered Pewter and Stainless...

Page 18: ...and nishes Contact dealer for all available mantel options Flush Panel Kits Flush panel kits may be used to replace louvered panels as desired for the See Through and Peninsula rebox models Available...

Page 19: ...8 29 1 8 29 1 8 29 1 8 H 41 1 8 41 1 8 41 1 8 41 1 8 I 1 1 4 1 1 4 1 1 4 1 1 4 J 6 1 8 6 1 8 6 1 8 6 1 8 K 8 1 2 8 1 2 8 1 2 8 1 2 L 6 6 6 6 M 27 5 8 27 5 8 27 5 8 27 5 8 N 36 7 8 36 7 8 36 7 8 36 7...

Page 20: ...D 3 8 COMBUSTIBLE CLEARANCE REQUIRED FROM TOP EDGE OF FIREBOX Combustible material clearance from front of rebox 36 minimum Sidewall Clearances The clearance from the inside of the rebox to perpendicu...

Page 21: ...Dimension when elevating rebox if installing on an elevated base Framing dimension A incudes a three inch clearance for standoffs on rebox Dimension C assumes use of 1 2 wall board ush to both front f...

Page 22: ...24117 0 0508 Page 22 SERVICE NOTES...

Page 23: ...24117 0 0508 Page 23 SERVICE NOTES...

Page 24: ...Page 24 EMPIRE EMPIRE Comfort Systems Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empir...

Reviews: