background image

25476-5-0612

Page 9

The firebox is designed to accept a 3/8-inch gas line for an approved 

vent-free gas logset. Have the line installed by a qualified service 

person in accordance with all building codes. consult local building 

codes to properly size the gas supply line leading to the 3/8-inch 

hook-up at the unit. the state of Massachusetts requires that a 

flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox. 

See 

Figure 11

. on  models with refractory brick panels installed, 

carefully remove the knockout in the refractory brick panel using a 

large standard screwdriver and hammer. First, place screwdriver in 

groove next to plug and pry sideways to pop out main plug. then 

remove the remaining concrete in hole with gentle tapping with ball 

peen hammer and/or screwdriver. a masonry drill and bit may also 

be used to create a clean hole for the gas line to pass through. 

See Figure 12.

When  installing  optional  ceramic  fiber  side  panels  into  firebox, 

lay panel on a flat surface. Remove the gas line knockout (round 

depression) in the appropriate side panel using a drill or utility knife.
When installing decorative stainless steel or reflective black 

liners, gas access holes in the bottom of the firebox are required. 

If  no  access  holes  are  available  in  the  bottom  of  the  firebox, 

see installation instructions for decorative liners for proper hole 

placement.

After the brick panel knockout is removed, the firebox wrap may 

have a round metal knockout that must be removed also. Use a 

screwdriver to punch out the metal knockout.
check gas type. Use only the gas type indicated on the gas log 

set rating plate. if the gas listed on the plate is not your type of gas 

supply, Do not inStaLL. contact your dealer for proper model.

Always use an external regulator for all LP fireboxes to reduce the 

supply tank pressure to a maximum of 14" w.c. this is in addition 

to the regulator fitted to the log set.

WaRning: connection DiRectLY to an UnRegULateD 
L.P. tanK can caUSe eXPLoSion. 

Install only a ANSI Z21.11.2 vent-free log set into this firebox. 

Figure 11

Extended hoods

If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that will 

extend out 2" farther out into the room. contact your local dealer for details.

Finishing

All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-

combustible material. 

Hearth extensions are recommended, but not required for these  fireboxes.

VB4H32BL

Standard Black

VB4H36BL

Standard Black

VB4H42BL

Standard Black

VB4H32BR

Polished Brass

VB4H36BR

Polished Brass

VB4H42BR

Polished Brass

VB4H32SS

Stainless Steel

VB4H36SS

Stainless Steel

VB4H42SS

Stainless Steel

VB4H32HP

Hammered Pewter

VB4H36HP

Hammered Pewter

VB4H42HP

Hammered Pewter

Ceramic Fiber Panel

INSTALLING hOOD (continued)

GAS LINE CONNECTION

Refractory Brick Panel

Figure 12

GAS ACCESS HOLES

Summary of Contents for VFD32FB0F-2

Page 1: ...ireplace size requirement DO NOT INSTALL a vent free log set IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION ANSI Z21 91 Ventless Fireplace Enclosures fo...

Page 2: ...Line Connection 9 Optional Fresh Air Kit Installation Instructions 10 12 Optional Single Speed Blower Installations Instructions 13 15 Junction Box Wiring Installation Instructions 16 Maintenance 16...

Page 3: ...val of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is opera...

Page 4: ...ustible side wall should not be less than 6 See Figure 1 Firebox Side and Back Clearances The firebox outer casing side and back flanges are zero clearance to combustibles Top Framing and Finishing Co...

Page 5: ...t meet the clearance requirements detailed below Grate Clearance The minimum clearance between the front legs of the grate and front edge of the firebox is 2 Leave at least 36 clearance from the front...

Page 6: ...or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you should have decided what compon...

Page 7: ...16 J 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 K 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 L 31 13 16 36 3 16 38 3 16 31 13 16 36 3 16 38 3 16 M 63 3 8 72 3 8 76 3 8 63 3 8 72 3 8 76 3 8 N 2 11 16 2 11 16 2 11 16...

Page 8: ...desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding firebox top to face panel then sl...

Page 9: ...s for proper hole placement After the brick panel knockout is removed the firebox wrap may have a round metal knockout that must be removed also Use a screwdriver to punch out the metal knockout Check...

Page 10: ...ust be installed prior to or at the time of firebox installation to framing The Fresh Air kit must be installed prior to the installation of wall board or other finishing materials around the unit Har...

Page 11: ...tside rain cap hood to the building 2 Secure the 4 dia duct to the Slide Assembly collar on the firebox with band clamps or screws installer supplied 3 Run the other end of the duct through the exteri...

Page 12: ...PREMIUM FIREBOXES 1 2 3 PARTS LIST INDEX NO PART NO DESCRIPTION 1 29259 Outside Air Vent Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer R 3580 PHILLIPS TRUSS HEAD SCREW 10 X QTY 2 R 2737 HEX...

Page 13: ...d Control Kit should be installed to activate pow er to the Firebox and control the operation of the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified...

Page 14: ...wires away from moving parts of the blower assem bly and retain wires together near the blower motor using the plastic purse clip provided 11 To complete the installation plug the power cord into the...

Page 15: ...move fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control knob slightly and turn c...

Page 16: ...box Install a UL listed cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to...

Page 17: ...14 R7051 Rod Screen Qty 2 15 R8137 Screen Curtain Qty 2 16 R8727 Hole Plug 17 25477 Blower Cover Plate 18 25490 Front Panel Flush 18 26444 Front Panel Louvered VFD32FB 0 2 SF 1 17149 Top Standoff Qty...

Page 18: ...le Plug 17 25477 Blower Cover Plate 18 26678 Front Panel Flush 18 26679 Front Panel Louvered VFD36FB 0 2 SF 1 17247 Top Standoff Qty 2 3 10554 Framing Bracket Qty 4 5 17162 Junction Box Assembly 6 R34...

Page 19: ...le Plug 17 25477 Blower Cover Plate 18 26689 Front Panel Flush 18 26690 Front Panel Louvered VFD42FB 0 2 SF 1 17247 Top Standoff Qty 2 3 10554 Framing Bracket Qty 4 5 17162 Junction Box Assembly 6 R34...

Page 20: ...25476 5 0612 Page 20 PARTS VIEW 1 16 4 2 7 6 5 8 12 11 10 9 14 14 17 13 3 15 18 18...

Page 21: ...V 1 Brick Liners Deluxe Firebox Contact dealer for all available optional liner kits Fresh Air Kit 1 2 3 Deluxe and Premium Fireboxes BVA 1 Frame Kits 3 Piece Frame Kits Black Stainless Steel or Hamme...

Page 22: ...ss Steel finishes Contact dealer for all avail able optional louver acces sories Bottom Trim Strip Available as optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for...

Page 23: ...st Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...

Page 24: ...ce must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify p...

Reviews: