The installation must conform with local codes or, in 

the absence of local codes, with the National Fuel Gas 

Code, ANSI Z223.1 (latest edition) and to the National 

electrical Code, ANSI/NFpA70 (latest edition).

NOTE: Installation and repair should be done by a quali

-

fied service person. The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required due 

to excessive lint from carpeting, bedding material, etc. 

It is imperative that control compartment, burners and 

circulating air passageways of the appliance be kept 

clean.

Any safety screen or guard removed for servicing an 

appliance must be replaced prior to operating the appli

-

ance. Provide adequate combustion and ventilation air.
The flow of combustion and ventilation air MUST NOT 

be obstructed.

provide adequate clearance around air openings into 

the  combustion  chamber  and  adequate  accessibility 

clearance for servicing and proper operation. NEVER 

obstruct the front opening of the appliance.

This  Empire  Comfort  Systems,  Inc.  firebox  and  its 

components have been tested and will operate safely 

when installed in accordance with this installation 

manual. Read all instructions before starting installation, 

then follow these instructions carefully during 

installation  to  maximize  firebox  benefit  and  safety. 

Report to your dealer any parts damaged in shipment.

The  Empire  Comfort  Systems,  Inc.  warranty  will  be 

voided by, and Empire Comfort Systems, Inc. disclaims 

any responsibility for the following actions:

-  Installation of any damaged firebox.

-  Modification of the firebox or any of the components 

parts thereof.

-  Installation  other  than  as  instructed  by  Empire 

Comfort Systems, Inc.

-  Installation and/or use of any component part 

or  accessory  not  approved  by  Empire  Comfort 

Systems,  Inc.  in  combination  or  assembly  with 

a  Empire  Comfort  Systems,  Inc.  firebox,  not 

withstanding  any  independent  testing  laboratory 

or other third party approval of such component 

part or accessory.

Any such action may create a possible fire hazard.

Consult your local building codes.
Firebox Screen.

The firebox screen must be in place when the firebox 

is operating.

Instructions to Installer

1.  installer must leave instruction manual with owner after 

installation.

2.  Installer must have owner fill out and mail warranty card 

supplied with firebox.

3.  installer should show owner how to start and operate 

log set that is installed into firebox.

Important

all correspondence should refer to complete Model number, 

Serial number.
notice:

  During  initial  firing  of  this  firebox  with  a  log  set 

installed, its paint will bake out, and smoke will occur. to 

prevent triggering of smoke alarms, ventilate the room in 

which the unit is installed.

Qualified Installing Agency

installation and replacement of gas piping, gas utilization 

equipment or accessories and repair and servicing of 

equipment shall be performed only by a qualified agency. 

The  term  "qualified  agency"  means  any  individual,  firm, 

corporation or company which either in person or through 

a representative is engaged in and is responsible for (a) 

the installation or replacement of gas piping or (b) the 

connection, installation, repair or servicing of equipment, 

who is experienced in such work, familiar with all precautions 

required and has complied with all the requirements of the 

authority having jurisdiction.

State of Massachusetts: the installation must be made 

by a licensed plumber or gas fitter in the Commonwealth 

of Massachusetts. the state of Massachusetts requires 

that a flexible appliance connector cannot exceed three 

feet in length.
Sellers of unvented propane or natural gas-fired 

supplemental room heaters shall provide to each 

purchaser a copy of 527 cMR 30 upon sale of the unit.
in the State of Massachusetts, unvented propane and 

natural  gas-fired  space  heaters  shall  be  prohibited  in 

bedrooms and bathrooms.

the installation must conform with local codes or, in the 

absence of local codes, with the national Fuel gas code, 

anSi Z223.1/nFPa 54.*

*available from the american national Standards institute, 

inc., 11 West 42nd St., new York, n.Y. 10036.

IMpORTANT SAFETy INFORMATION

INTRODUCTION

Summary of Contents for VFD32FB0F-2

Page 1: ...ireplace size requirement DO NOT INSTALL a vent free log set IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION ANSI Z21 91 Ventless Fireplace Enclosures fo...

Page 2: ...Line Connection 9 Optional Fresh Air Kit Installation Instructions 10 12 Optional Single Speed Blower Installations Instructions 13 15 Junction Box Wiring Installation Instructions 16 Maintenance 16...

Page 3: ...val of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is opera...

Page 4: ...ustible side wall should not be less than 6 See Figure 1 Firebox Side and Back Clearances The firebox outer casing side and back flanges are zero clearance to combustibles Top Framing and Finishing Co...

Page 5: ...t meet the clearance requirements detailed below Grate Clearance The minimum clearance between the front legs of the grate and front edge of the firebox is 2 Leave at least 36 clearance from the front...

Page 6: ...or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you should have decided what compon...

Page 7: ...16 J 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 K 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 L 31 13 16 36 3 16 38 3 16 31 13 16 36 3 16 38 3 16 M 63 3 8 72 3 8 76 3 8 63 3 8 72 3 8 76 3 8 N 2 11 16 2 11 16 2 11 16...

Page 8: ...desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding firebox top to face panel then sl...

Page 9: ...s for proper hole placement After the brick panel knockout is removed the firebox wrap may have a round metal knockout that must be removed also Use a screwdriver to punch out the metal knockout Check...

Page 10: ...ust be installed prior to or at the time of firebox installation to framing The Fresh Air kit must be installed prior to the installation of wall board or other finishing materials around the unit Har...

Page 11: ...tside rain cap hood to the building 2 Secure the 4 dia duct to the Slide Assembly collar on the firebox with band clamps or screws installer supplied 3 Run the other end of the duct through the exteri...

Page 12: ...PREMIUM FIREBOXES 1 2 3 PARTS LIST INDEX NO PART NO DESCRIPTION 1 29259 Outside Air Vent Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer R 3580 PHILLIPS TRUSS HEAD SCREW 10 X QTY 2 R 2737 HEX...

Page 13: ...d Control Kit should be installed to activate pow er to the Firebox and control the operation of the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified...

Page 14: ...wires away from moving parts of the blower assem bly and retain wires together near the blower motor using the plastic purse clip provided 11 To complete the installation plug the power cord into the...

Page 15: ...move fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control knob slightly and turn c...

Page 16: ...box Install a UL listed cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to...

Page 17: ...14 R7051 Rod Screen Qty 2 15 R8137 Screen Curtain Qty 2 16 R8727 Hole Plug 17 25477 Blower Cover Plate 18 25490 Front Panel Flush 18 26444 Front Panel Louvered VFD32FB 0 2 SF 1 17149 Top Standoff Qty...

Page 18: ...le Plug 17 25477 Blower Cover Plate 18 26678 Front Panel Flush 18 26679 Front Panel Louvered VFD36FB 0 2 SF 1 17247 Top Standoff Qty 2 3 10554 Framing Bracket Qty 4 5 17162 Junction Box Assembly 6 R34...

Page 19: ...le Plug 17 25477 Blower Cover Plate 18 26689 Front Panel Flush 18 26690 Front Panel Louvered VFD42FB 0 2 SF 1 17247 Top Standoff Qty 2 3 10554 Framing Bracket Qty 4 5 17162 Junction Box Assembly 6 R34...

Page 20: ...25476 5 0612 Page 20 PARTS VIEW 1 16 4 2 7 6 5 8 12 11 10 9 14 14 17 13 3 15 18 18...

Page 21: ...V 1 Brick Liners Deluxe Firebox Contact dealer for all available optional liner kits Fresh Air Kit 1 2 3 Deluxe and Premium Fireboxes BVA 1 Frame Kits 3 Piece Frame Kits Black Stainless Steel or Hamme...

Page 22: ...ss Steel finishes Contact dealer for all avail able optional louver acces sories Bottom Trim Strip Available as optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for...

Page 23: ...st Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...

Page 24: ...ce must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify p...