empire comfort Systems inc. warranties this hearth product to be free from defects at the time of purchase and for the periods speci-

fied below.  Hearth products must be installed by a qualified technician and must be maintained and operated safely, in accordance with 

the instructions in the owner’s manual.  this warranty applies to the original purchaser only and is not transferable.  all warranty repairs 

must be accomplished by a qualified gas appliance technician.

Limited Lifetime Parts Warranty with a Five-Year Limited Labor Warranty – Combustion Chamber and Heat Exchanger

 

if the combustion chamber or heat exchanger (see parts list) fails because of defective workmanship or material, empire will 

repair or replace at empire’s option.

 

Within five years from the date of purchase, Empire will pay reasonable labor to have the defective part repaired or replaced at 

empire’s option.

Limited Five-Year Parts & Labor Warranty – All Other Components 

(except Remote controls, thermostats, accessories and Replacement Parts)

 

Should any part fail because of defective workmanship or material within five years from the date of purchase, Empire will 

repair or replace at empire’s option.

 

Within five years from the date of purchase, Empire will pay reasonable labor to have that defect repaired at Empire’s option.

Limited One-Year Parts Warranty – Remote Controls, Thermostats, Accessories, and Parts

 

Should any remote control, thermostat, accessory, or other part fail because of defective workmanship within one year from 

the date of purchase, empire will repair or replace at empire’s option.

Duties Of The Owner

 

The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap

-

pliance.

 

a bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish warranty period.

 

Ready access to the appliance for service.

What Is Not Covered

 

Damages that might result from the use, misuse, or improper installation of this appliance.

 

travel, diagnostic costs and freight charges on warranted parts to and from the factory.

 

claims that do not involve defective workmanship or materials.

 

Unauthorized service or parts replacements.

 

Removal and reinstallation cost.

 

inoperable due to improper or lack of maintenance.

How To Get Service

 

to make a claim under this warranty, please have your receipt available and contact your installing dealer.  Provide the dealer 

with the model number, serial number, type of gas, and purchase verification.  The installing dealer is responsible for providing service and 

will contact the factory to initiate any warranted parts replacements.  empire will make replacement parts available at the factory.  Shipping 

expenses are not covered.

 

if, after contacting your empire dealer, service received has not been satisfactory, contact: consumer Relations Department, 

empire comfort Systems inc., Po Box 529, Belleville, illinois 62222, or send an e-mail to [email protected] with “consumer Rela-

tions” in the subject line.

Your Rights Under State Law

 

This warranty gives your specific legal rights, and you may also have other rights, which vary from state to state.

wARRANTy

EMPIRE

EMPIRE

Comfort Systems

empire comfort Systems inc.

918 Freeburg ave. Belleville, iL  62220

if you have a general question about our products, please e-mail us at 

[email protected]

if you have a service or repair question, please contact your dealer.

www.empirecomfort.com

Summary of Contents for VFD32FB0F-2

Page 1: ...ireplace size requirement DO NOT INSTALL a vent free log set IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION ANSI Z21 91 Ventless Fireplace Enclosures fo...

Page 2: ...Line Connection 9 Optional Fresh Air Kit Installation Instructions 10 12 Optional Single Speed Blower Installations Instructions 13 15 Junction Box Wiring Installation Instructions 16 Maintenance 16...

Page 3: ...val of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is opera...

Page 4: ...ustible side wall should not be less than 6 See Figure 1 Firebox Side and Back Clearances The firebox outer casing side and back flanges are zero clearance to combustibles Top Framing and Finishing Co...

Page 5: ...t meet the clearance requirements detailed below Grate Clearance The minimum clearance between the front legs of the grate and front edge of the firebox is 2 Leave at least 36 clearance from the front...

Page 6: ...or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you should have decided what compon...

Page 7: ...16 J 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 K 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 L 31 13 16 36 3 16 38 3 16 31 13 16 36 3 16 38 3 16 M 63 3 8 72 3 8 76 3 8 63 3 8 72 3 8 76 3 8 N 2 11 16 2 11 16 2 11 16...

Page 8: ...desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding firebox top to face panel then sl...

Page 9: ...s for proper hole placement After the brick panel knockout is removed the firebox wrap may have a round metal knockout that must be removed also Use a screwdriver to punch out the metal knockout Check...

Page 10: ...ust be installed prior to or at the time of firebox installation to framing The Fresh Air kit must be installed prior to the installation of wall board or other finishing materials around the unit Har...

Page 11: ...tside rain cap hood to the building 2 Secure the 4 dia duct to the Slide Assembly collar on the firebox with band clamps or screws installer supplied 3 Run the other end of the duct through the exteri...

Page 12: ...PREMIUM FIREBOXES 1 2 3 PARTS LIST INDEX NO PART NO DESCRIPTION 1 29259 Outside Air Vent Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer R 3580 PHILLIPS TRUSS HEAD SCREW 10 X QTY 2 R 2737 HEX...

Page 13: ...d Control Kit should be installed to activate pow er to the Firebox and control the operation of the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified...

Page 14: ...wires away from moving parts of the blower assem bly and retain wires together near the blower motor using the plastic purse clip provided 11 To complete the installation plug the power cord into the...

Page 15: ...move fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control knob slightly and turn c...

Page 16: ...box Install a UL listed cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to...

Page 17: ...14 R7051 Rod Screen Qty 2 15 R8137 Screen Curtain Qty 2 16 R8727 Hole Plug 17 25477 Blower Cover Plate 18 25490 Front Panel Flush 18 26444 Front Panel Louvered VFD32FB 0 2 SF 1 17149 Top Standoff Qty...

Page 18: ...le Plug 17 25477 Blower Cover Plate 18 26678 Front Panel Flush 18 26679 Front Panel Louvered VFD36FB 0 2 SF 1 17247 Top Standoff Qty 2 3 10554 Framing Bracket Qty 4 5 17162 Junction Box Assembly 6 R34...

Page 19: ...le Plug 17 25477 Blower Cover Plate 18 26689 Front Panel Flush 18 26690 Front Panel Louvered VFD42FB 0 2 SF 1 17247 Top Standoff Qty 2 3 10554 Framing Bracket Qty 4 5 17162 Junction Box Assembly 6 R34...

Page 20: ...25476 5 0612 Page 20 PARTS VIEW 1 16 4 2 7 6 5 8 12 11 10 9 14 14 17 13 3 15 18 18...

Page 21: ...V 1 Brick Liners Deluxe Firebox Contact dealer for all available optional liner kits Fresh Air Kit 1 2 3 Deluxe and Premium Fireboxes BVA 1 Frame Kits 3 Piece Frame Kits Black Stainless Steel or Hamme...

Page 22: ...ss Steel finishes Contact dealer for all avail able optional louver acces sories Bottom Trim Strip Available as optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for...

Page 23: ...st Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...

Page 24: ...ce must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify p...