Some people cannot smell well. Some people cannot smell the 

odor of the chemical put into the gas. You must find out if you 

can smell the odorant in propane.

 Smoking can decrease your 

ability to smell. Being around an odor for a time can affect your 

sensitivity or ability to detect that odor. Sometimes other odors in 

the area mask the gas odor. People may not smell the gas odor 

or their minds are on something else. Thinking about smelling a 

gas odor can make it easier to smell.

The odorant in Lp-gas is colorless, and it can fade under some 

circumstances. 

For example, if there is an underground leak, the 

movement of the gas through soil can filter the odorant. Odorants 

in LP-Gas also are subject to oxidation. This fading can occur if 

there is rust inside the storage tank or in iron gas pipes.

by point with the members of your household. Someday 

when there may not be a minute to lose, everyone's safety 

will depend on knowing exactly what to do. If, after read-

ing the following information, you feel you still need more 

information, please contact your gas supplier.

Propane (LP-Gas) is a flammable gas which can cause fires 

and explosions. In its natural state, propane is odorless and 

colorless. You may not know all the following safety precau-

tions which can protect both you and your family from an 

accident. Read them carefully now, then review them point 

The odorant in escaped gas can adsorb or absorb onto or into 

walls, masonry and other materials and fabrics in a room. That 

will take some of the odorant out of the gas, reducing its odor 

intensity.
LP-Gas  may  stratify  in  a  closed  area,  and  the  odor  intensity 

could vary at different levels. Since it is heavier than air, there 

may be more odor at lower levels. Always be sensitive to the 

slightest gas odor. If you detect any odor, treat it as a serious 

leak. Immediately go into action as instructed earlier.

• 

Learn to recognize the odor of Lp-gas. 

Your local LP-Gas 

Dealer can give you a "Scratch and Sniff" pamphlet. Use it to 

find out what the propane odor smells like. If you suspect that 

your LP-Gas has a weak or abnormal odor, call your LP-Gas 

Dealer.

•  If you are not qualified, do not light pilot lights, perform service, 

or make adjustments to appliances on the LP-Gas system. If 

you are qualified, consciously think about the odor of LP-Gas 

prior to and while lighting pilot lights or performing service or 

making adjustments.

•  Sometimes a basement or a closed-up house has a musty 

smell that can cover up the LP-Gas odor. Do not try to light 

pilot lights, perform service, or make adjustments in an area 

where the conditions are such that you may not detect the 

odor if there has been a leak of LP-Gas.

•  Odor fade, due to oxidation by rust or adsorption on walls of 

new cylinders and tanks, is possible. Therefore, people should 

be particularly alert and careful when new tanks or cylinders 

are placed in service. Odor fade can occur in new tanks, or 

reinstalled old tanks, if they are filled and allowed to set too 

long before refilling. Cylinders and tanks which have been 

out of service for a time may develop internal rust which will 

cause odor fade. If such conditions are suspected to exist, 

a periodic sniff test of the gas is advisable. 

If you have any 

question about the gas odor, call your Lp-gas dealer. A 

periodic sniff test of the Lp-gas is a good safety measure 

under any condition.

•  If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the 

same immediate action recommended above for the occasion 

when you do detect the odorized LP-Gas.

•  If you experience a complete "gas out," (the container is un

-

der no vapor pressure), turn the tank valve off immediately. 

If the container valve is left on, the container may draw in 

some air through openings such as pilot light orifices. If this 

occurs, some new internal rusting could occur. If the valve is 

left open, then treat the container as a new tank. Always be 

sure your container is under vapor pressure by turning it off 

at the container before it goes completely empty or having it 

refilled before it is completely empty.

• 

Do  not  operate  electric  switches,  light  matches,  use  your 

phone. Do not do anything that could ignite the gas.

•   Get everyone out of the building, vehicle, trailer, or area. Do 

that IMMEDIATELY.

•   Close all gas tank or cylinder supply valves.

•   LP-Gas is heavier than air and may settle in low areas such 

as basements. When you have reason to suspect a gas leak, 

keep out of basements and other low areas. Stay out until 

firefighters declare them to be safe.

•   Use your neighbor's phone and call a trained LP-Gas service 

person and the fire department. Even though you may not 

continue to smell gas, do not turn on the gas again. Do not 

re-enter the building, vehicle, trailer, or area.

•   Finally, let the service man and firefighters check for escaped 

gas. Have them air out the area before you return. Properly 

trained LP-Gas service people should repair the leak, then 

check and relight the gas appliance for you.

SOME pOINTS TO REMEMBER

NO ODOR DETECTED - ODOR FADE

Lp-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the Lp-Gas. 

That's your signal to go into immediate action!

SAFETY INFORMATION FOR USERS OF LP-GAS

Summary of Contents for VFD26FM20C-2

Page 1: ...page 8 WARNING If not installed operated and main tained in accordance with the manufacturer s instructions this product could expose you to substances in fuel or from fuel combustion which can cause...

Page 2: ...L 16 OPERATION INSTRUCTIONS FLAME APPEARANCE 16 10 000 BTU MILLIVOLT LIGHTING INSTRUCTIONS 17 MILLIVOLT LIGHTING INSTRUCTIONS 18 HYDRAULIC THERMOSTAT LIGHTING INSTRUCTIONS 19 PILOT FLAME CHARACTERISTI...

Page 3: ...all not be installed in a bedroom or bathroom Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the...

Page 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Page 5: ...1 000 feet 305m above sea level Contact the manufacturer or your gas company before changing spud orifice size WARNING Failure to keep the primary air opening s of the burner s clean may result in so...

Page 6: ...own in Figure 2 for corner rough opening Be sure to provide gas line for fireplace and electrical power for optional blower assembly 1 Attach two 2 nailing flanges to firebox sides with two 2 10 x 1 2...

Page 7: ...NE OPENING JUNCTION BOX ASSEMBLY GAS LINE OPENING J I K B C G A D E Figure 4 VFD26 Series Dimensions Index Letter Dimension A 30 1 4 768mm B 30 762mm C 13 1 8 333mm D 18 1 8 460mm E 26 660mm G 25 635m...

Page 8: ...at FREC Electric Remote Control FWS 1 Wall Switch TMV Wall Thermostat Millivolt Reed Switch TRW Wireless Remote Wall Thermostat Water vapor is a by product of gas combustion An unvented room heater pr...

Page 9: ...are confined spaces Furnaces installed in a confined space which supply heated air to areas outside the space must draw return air from outside the space through tightly sealed return air ducts A conf...

Page 10: ...air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one with 12 of the floor Connect these items directly to the outdoors or spaces open...

Page 11: ...l Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flex ible appliance connector cannot exceed three fe...

Page 12: ...the top of the fireplace opening to the ceiling should not be less than 36 inches Mantel Clearances for Built in Installation Figure 9 Do not attach combustible material to the mantel of your firepla...

Page 13: ...Remove shrink wrap and logs from fireplace 6 Place back base and fireplace in desired location 7 Connect gas line and electrical wiring at this time in accor dance with local codes 8 Place mantel ass...

Page 14: ...ogs per the Log Placement Instructions See Page 15 14 Install hood See Page 22 9 Attach mantel assembly to studs in the wall through the back brace using two 2 3 drywall screws provided 10 Slide front...

Page 15: ...4 This step is optional for VFD26FP3L10 log sets Place front twig 5 onto 1 log and flat area on 3 log The bottom of the front twig is to be placed behind the grate tang that is second from the left At...

Page 16: ...burner as well as the main flame should be visually checked as the log set is installed In normal operation at full rate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOT...

Page 17: ...m louver assembly if applicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob c...

Page 18: ...pplicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from P...

Page 19: ...ance 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable Lighting Instructions 7 Turn gas control knob counterclo...

Page 20: ...Troubleshooting page 25 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip flame clean the Oxygen Depletion Sensor as follows 1 Clean the ODS pilot by...

Page 21: ...is the OFF position PILOT is the PILOT position VFD26F M P 3 Max 20 000 BTU HR Min 14 000 BTU HR VFD26FP3L10 Max 10 000 Min N A VFD26F M P 2 Main Burner Operation The gas control modulates from a min...

Page 22: ...ireplace Attach top frame to fireplace Use two 2 8 x 1 2 Phillips screws for top frame 5 Replace bottom louver 6 Replace top louver 3 PIECE FRAME KIT SIDE TRIM Figure 21 HOOD INSTRUCTIONS 1 Remove upp...

Page 23: ...urner assembly NOTICE Do not let remote control receiver come in contact with burner assembly On circulating vent free firebox install remote control receiver behind bottom louver Refer to remote cont...

Page 24: ...L ELECTRICAL CODE ANSI NFPA 70 LAT EST EDITION A factory installed junction box is located on the lower right side of the fireplace Wiring must be fed to the junction box and attached to the receptacl...

Page 25: ...setting is not correct Replace gas regula tor 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pre...

Page 26: ...R10947 WIRE ASSEMBLY VFD26F M P 3LP PART NUMBERS 10 R3623 PILOT ASSEMBLY 11 21590 PILOT BRACKET 14 R9022 BURNER TUBE 16 P182 ORIFICE 19 23493 TUBING ASSEMBLY 21 R3625 VALVE 23 23496 TUBING ASSEMBLY 30...

Page 27: ...e 27 PARTS VIEW 5 PIECE LOG Y ASSEMBL MILLIVOLT VALVE Y ASSEMBL THERMOSTATIC VALVE Y ASSEMBL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 19 20 20 21 21 22 23 23 24 25 26 27 28 29 29 30 31 18 32 33...

Page 28: ...ireplace The magnets on the bottom of speed control will sufficiently hold the speed control in place 13 Attach fan control bracket to upper right side of firebox with one 10 x 1 2 hex screw provided...

Page 29: ...r Kit 110 VOLT AC JUNCTION BOX WHITE SPEED CONTROL FAN SWITCH GROUND BLACK FAN WHITE BLACK SWITCH BRACKET FBBX Wiring Diagram FBBX BLOWER KIT EXTENSION INSTALLATION INSTRUCTIONS cont FBB4 OPTIONAL VAR...

Page 30: ...e 1 side panel into firebox 5 Align clearance hole on brick panel bracket with screw hole in the left or right interior top of firebox Use two 2 10 x 1 2 screws to attach brick panel bracket to interi...

Page 31: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Page 32: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: