background image

27525-2-0411

Page 17

WARNING:

 If you do not follow these instructions exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life.

A.  This  appliance  has  a  pilot  which  must  be  lighted  by 

hand. When lighting the pilot, follow these instructions 

exactly.

B.  BEFORE LIGHTING, smell all around the appliance area 

for gas. Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor.

  WHAT TO DO IF YOU SMELL GAS

 

•  Do not try to light any appliance

 

•  Do not touch any electrical switch; Do not use any 

phone in your building

 

•  Immediately call your gas supplier from a neighbor's 

phone. Follow the gas supplier's instructions.

 

•  If you cannot reach your gas supplier, call the fire 

department.

C.  Use only your hand to push in or turn the gas control 

knob.  Never  use  tools.  If  the  knob  will  not  push  in  or 

turn by hand, don't try to repair it, call a qualified service 

technician. Force or attempted repair may result in a fire 

or explosion.

D.  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control system 

and any gas control which has been under water.

1.  Open bottom louver assembly (if applicable).
2.  Set REMOTE/OFF/ON switch to "OFF."
3.  Turn off all electric power to the appliance if service is to be 

performed (if applicable).

4.  Push in gas control knob slightly and turn clockwise 

 

to "OFF". Do not force.

5.  Close bottom louver assembly (if applicable).

1.  STOP! Read the safety information above on this page.
2.  Open bottom louver assembly (if applicable).
3.  Set REMOTE/OFF/ON switch to 

"OFF".

4.  Turn off all electric power to the 

appliance (if applicable).

5.  Push in gas control knob slightly 

and turn clockwise 

 to "OFF".   

 

   

NOTE: Knob cannot be turned from "PILOT" 

to  "OFF"  unless  knob  is  pushed  in  slightly. 

Do not force.

6.  Wait ten (10) minutes to clear out any gas. 

Then smell for gas, including near 

the floor. If you smell gas, STOP! 

Follow "B" in the safety information 

above. If you do not smell gas, go 

to the next step.

7.  Find pilot - Follow metal tube from 

gas  control.  The  pilot  is  located 

next to the burner, near the right 

side.

8.  Turn  gas  control  knob  counterclockwise 

  

to "PILOT".

9.  Push in control knob all the way and hold in. Repeatedly push 

the Piezo Ignitor Button until the pilot is lit. Continue to hold 

the control knob in for about one (1) minute after the pilot is 

lit. Release knob, and it will pop back up. Pilot should remain 

lit. If it goes out, repeat steps 5 through 9.

 

• 

If knob does not pop up when released, STOP and IM

-

MEDIATELY  call  a  qualified  service  technician  or  gas 

supplier.

 

• 

If the pilot will not stay lit after several tries, turn the gas 

control knob to "OFF" and call your service technician or 

gas supplier.

10.  Turn gas control knob counterclockwise 

 to "ON".

11.  Set REMOTE/OFF/ON switch to desired setting. 
12.  Turn on all electric power to the appliance (if applicable).
13.  Close bottom louver assembly (if applicable).

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE

(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE

(LPG)

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE

(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE

(LPG)

10,000 BTU MILLIVOLT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO AppLIANCE

Summary of Contents for VFD26FM20C-2

Page 1: ...page 8 WARNING If not installed operated and main tained in accordance with the manufacturer s instructions this product could expose you to substances in fuel or from fuel combustion which can cause...

Page 2: ...L 16 OPERATION INSTRUCTIONS FLAME APPEARANCE 16 10 000 BTU MILLIVOLT LIGHTING INSTRUCTIONS 17 MILLIVOLT LIGHTING INSTRUCTIONS 18 HYDRAULIC THERMOSTAT LIGHTING INSTRUCTIONS 19 PILOT FLAME CHARACTERISTI...

Page 3: ...all not be installed in a bedroom or bathroom Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the...

Page 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Page 5: ...1 000 feet 305m above sea level Contact the manufacturer or your gas company before changing spud orifice size WARNING Failure to keep the primary air opening s of the burner s clean may result in so...

Page 6: ...own in Figure 2 for corner rough opening Be sure to provide gas line for fireplace and electrical power for optional blower assembly 1 Attach two 2 nailing flanges to firebox sides with two 2 10 x 1 2...

Page 7: ...NE OPENING JUNCTION BOX ASSEMBLY GAS LINE OPENING J I K B C G A D E Figure 4 VFD26 Series Dimensions Index Letter Dimension A 30 1 4 768mm B 30 762mm C 13 1 8 333mm D 18 1 8 460mm E 26 660mm G 25 635m...

Page 8: ...at FREC Electric Remote Control FWS 1 Wall Switch TMV Wall Thermostat Millivolt Reed Switch TRW Wireless Remote Wall Thermostat Water vapor is a by product of gas combustion An unvented room heater pr...

Page 9: ...are confined spaces Furnaces installed in a confined space which supply heated air to areas outside the space must draw return air from outside the space through tightly sealed return air ducts A conf...

Page 10: ...air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one with 12 of the floor Connect these items directly to the outdoors or spaces open...

Page 11: ...l Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flex ible appliance connector cannot exceed three fe...

Page 12: ...the top of the fireplace opening to the ceiling should not be less than 36 inches Mantel Clearances for Built in Installation Figure 9 Do not attach combustible material to the mantel of your firepla...

Page 13: ...Remove shrink wrap and logs from fireplace 6 Place back base and fireplace in desired location 7 Connect gas line and electrical wiring at this time in accor dance with local codes 8 Place mantel ass...

Page 14: ...ogs per the Log Placement Instructions See Page 15 14 Install hood See Page 22 9 Attach mantel assembly to studs in the wall through the back brace using two 2 3 drywall screws provided 10 Slide front...

Page 15: ...4 This step is optional for VFD26FP3L10 log sets Place front twig 5 onto 1 log and flat area on 3 log The bottom of the front twig is to be placed behind the grate tang that is second from the left At...

Page 16: ...burner as well as the main flame should be visually checked as the log set is installed In normal operation at full rate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOT...

Page 17: ...m louver assembly if applicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob c...

Page 18: ...pplicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from P...

Page 19: ...ance 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable Lighting Instructions 7 Turn gas control knob counterclo...

Page 20: ...Troubleshooting page 25 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip flame clean the Oxygen Depletion Sensor as follows 1 Clean the ODS pilot by...

Page 21: ...is the OFF position PILOT is the PILOT position VFD26F M P 3 Max 20 000 BTU HR Min 14 000 BTU HR VFD26FP3L10 Max 10 000 Min N A VFD26F M P 2 Main Burner Operation The gas control modulates from a min...

Page 22: ...ireplace Attach top frame to fireplace Use two 2 8 x 1 2 Phillips screws for top frame 5 Replace bottom louver 6 Replace top louver 3 PIECE FRAME KIT SIDE TRIM Figure 21 HOOD INSTRUCTIONS 1 Remove upp...

Page 23: ...urner assembly NOTICE Do not let remote control receiver come in contact with burner assembly On circulating vent free firebox install remote control receiver behind bottom louver Refer to remote cont...

Page 24: ...L ELECTRICAL CODE ANSI NFPA 70 LAT EST EDITION A factory installed junction box is located on the lower right side of the fireplace Wiring must be fed to the junction box and attached to the receptacl...

Page 25: ...setting is not correct Replace gas regula tor 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pre...

Page 26: ...R10947 WIRE ASSEMBLY VFD26F M P 3LP PART NUMBERS 10 R3623 PILOT ASSEMBLY 11 21590 PILOT BRACKET 14 R9022 BURNER TUBE 16 P182 ORIFICE 19 23493 TUBING ASSEMBLY 21 R3625 VALVE 23 23496 TUBING ASSEMBLY 30...

Page 27: ...e 27 PARTS VIEW 5 PIECE LOG Y ASSEMBL MILLIVOLT VALVE Y ASSEMBL THERMOSTATIC VALVE Y ASSEMBL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 19 20 20 21 21 22 23 23 24 25 26 27 28 29 29 30 31 18 32 33...

Page 28: ...ireplace The magnets on the bottom of speed control will sufficiently hold the speed control in place 13 Attach fan control bracket to upper right side of firebox with one 10 x 1 2 hex screw provided...

Page 29: ...r Kit 110 VOLT AC JUNCTION BOX WHITE SPEED CONTROL FAN SWITCH GROUND BLACK FAN WHITE BLACK SWITCH BRACKET FBBX Wiring Diagram FBBX BLOWER KIT EXTENSION INSTALLATION INSTRUCTIONS cont FBB4 OPTIONAL VAR...

Page 30: ...e 1 side panel into firebox 5 Align clearance hole on brick panel bracket with screw hole in the left or right interior top of firebox Use two 2 10 x 1 2 screws to attach brick panel bracket to interi...

Page 31: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Page 32: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: