background image

27525-2-0411

Page 28

 For Unvented Gas Fireplace Model  VFD26F(M,p)2, VFD26F(M,p)3

FBBX BLOWER KIT EXTENSION INSTALLATION INSTRUC-

TIONS

Disregard  FBB4  Blower  Installation  Instructions.  Follow  the  in-

stallation instructions with your FBBX blower extension kit or the 

VFD26 Instruction Manual.

Attention: 

If installed, do not damage gas inlet supply line when 

blower assembly is inserted into fireplace. Removal of the gas inlet 

supply line will be necessary.

1.   Remove blower parts from the FBB4 kit and the parts from the 

FBBX kit.

2.  Remove fan control from wire harness in the FBB4 kit.

3.  Attach  the  fan  control  to  the  fan  control  bracket  using  the 

2-8x1/4” screws provided.

4.  If installed, turn OFF gas supply to fireplace.

5.  If applicable, turn OFF electric supply to fireplace.

6.  Lower bottom louver on fireplace.

7.  Remove upper louver.

8.  Remove screen frame assembly

9.  If applicable, remove logs from burner assembly.

10.  Remove  burner  assembly  from  firebox  (3  screws). 

 

See Figure 26.

11.  Position  blower  assembly  behind  gas  valve,  align  notch  on 

back of blower assembly with center screw on fireplace back 

and push blower assembly against fireplace back. The bower 

wheel must be centered with the back wall of the fireplace. 

Place blower assembly against the back wall. The magnets 

on the back and bottom of blower assembly will sufficiently 

hold blower assembly in place.

12.  Position speed control to the right of gas valve. Attach speed 

control to bottom of fireplace. The magnets on the bottom of 

speed control will sufficiently hold the speed control in place.

13.  Attach fan control bracket to upper right side of firebox with 

one #10 x 1/2 hex screw provided. See Figure 25.

14.  Attach wire harness from the FBBX kit to the terminals on the 

fan control.

15.  Route the wire harness along the right side of the firebox.

16.  Connect the wire harness from the fan control to the wire har-

ness from the speed control.

17.  Insert power cord plug into junction box.

18.  Replace burner assembly in firebox with the three (3) screws 

removed in Step 10.

19.  If applicable, replace logs onto burner assembly.

20.  Replace screen frame assembly.

21.  Install upper louver. Close bottom louver on fireplace.

NOTICE

:

  This blower is equipped with a heat activated fan control 

switch. Fan will operate when the fireplace warms up, 

and will turn off when the fireplace cools down.

22.  Installation of FBB4 and FBBX option variable speed blower 

assembly is completed.

Blower Motor

The blower motor does not have oiling holes. Do not attempt to oil 

the blower motor.

Blower Wheels

The blower wheels will collect lint and could require periodic clean

-

ing. If the air output decreases or the noise level increases, it indi-

cates a dirty blower wheel. Remove fan and clean blower wheels.

 

WARNING

Unplugging of blower accessory will not stop the heater from cy-

cling. To turn off gas to the heater (millivolt model): push in gas 

control knob slightly and turn clockwise to OFF.” Do not force. 

FAN SWITCH

FAN KIT

SPEED CONTROL

JUNCTION BOX

SWITCH

BRACKET

FAN CONTROL

BRACKET

SCREW HOLE

BRICK LINER

RETAINER

SCREW HOLE

Figure 25

REMOVE

REMOVE

REMOVE

Figure 26

Summary of Contents for VFD26FM20C-2

Page 1: ...page 8 WARNING If not installed operated and main tained in accordance with the manufacturer s instructions this product could expose you to substances in fuel or from fuel combustion which can cause...

Page 2: ...L 16 OPERATION INSTRUCTIONS FLAME APPEARANCE 16 10 000 BTU MILLIVOLT LIGHTING INSTRUCTIONS 17 MILLIVOLT LIGHTING INSTRUCTIONS 18 HYDRAULIC THERMOSTAT LIGHTING INSTRUCTIONS 19 PILOT FLAME CHARACTERISTI...

Page 3: ...all not be installed in a bedroom or bathroom Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the...

Page 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Page 5: ...1 000 feet 305m above sea level Contact the manufacturer or your gas company before changing spud orifice size WARNING Failure to keep the primary air opening s of the burner s clean may result in so...

Page 6: ...own in Figure 2 for corner rough opening Be sure to provide gas line for fireplace and electrical power for optional blower assembly 1 Attach two 2 nailing flanges to firebox sides with two 2 10 x 1 2...

Page 7: ...NE OPENING JUNCTION BOX ASSEMBLY GAS LINE OPENING J I K B C G A D E Figure 4 VFD26 Series Dimensions Index Letter Dimension A 30 1 4 768mm B 30 762mm C 13 1 8 333mm D 18 1 8 460mm E 26 660mm G 25 635m...

Page 8: ...at FREC Electric Remote Control FWS 1 Wall Switch TMV Wall Thermostat Millivolt Reed Switch TRW Wireless Remote Wall Thermostat Water vapor is a by product of gas combustion An unvented room heater pr...

Page 9: ...are confined spaces Furnaces installed in a confined space which supply heated air to areas outside the space must draw return air from outside the space through tightly sealed return air ducts A conf...

Page 10: ...air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one with 12 of the floor Connect these items directly to the outdoors or spaces open...

Page 11: ...l Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flex ible appliance connector cannot exceed three fe...

Page 12: ...the top of the fireplace opening to the ceiling should not be less than 36 inches Mantel Clearances for Built in Installation Figure 9 Do not attach combustible material to the mantel of your firepla...

Page 13: ...Remove shrink wrap and logs from fireplace 6 Place back base and fireplace in desired location 7 Connect gas line and electrical wiring at this time in accor dance with local codes 8 Place mantel ass...

Page 14: ...ogs per the Log Placement Instructions See Page 15 14 Install hood See Page 22 9 Attach mantel assembly to studs in the wall through the back brace using two 2 3 drywall screws provided 10 Slide front...

Page 15: ...4 This step is optional for VFD26FP3L10 log sets Place front twig 5 onto 1 log and flat area on 3 log The bottom of the front twig is to be placed behind the grate tang that is second from the left At...

Page 16: ...burner as well as the main flame should be visually checked as the log set is installed In normal operation at full rate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOT...

Page 17: ...m louver assembly if applicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob c...

Page 18: ...pplicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from P...

Page 19: ...ance 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable Lighting Instructions 7 Turn gas control knob counterclo...

Page 20: ...Troubleshooting page 25 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip flame clean the Oxygen Depletion Sensor as follows 1 Clean the ODS pilot by...

Page 21: ...is the OFF position PILOT is the PILOT position VFD26F M P 3 Max 20 000 BTU HR Min 14 000 BTU HR VFD26FP3L10 Max 10 000 Min N A VFD26F M P 2 Main Burner Operation The gas control modulates from a min...

Page 22: ...ireplace Attach top frame to fireplace Use two 2 8 x 1 2 Phillips screws for top frame 5 Replace bottom louver 6 Replace top louver 3 PIECE FRAME KIT SIDE TRIM Figure 21 HOOD INSTRUCTIONS 1 Remove upp...

Page 23: ...urner assembly NOTICE Do not let remote control receiver come in contact with burner assembly On circulating vent free firebox install remote control receiver behind bottom louver Refer to remote cont...

Page 24: ...L ELECTRICAL CODE ANSI NFPA 70 LAT EST EDITION A factory installed junction box is located on the lower right side of the fireplace Wiring must be fed to the junction box and attached to the receptacl...

Page 25: ...setting is not correct Replace gas regula tor 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pre...

Page 26: ...R10947 WIRE ASSEMBLY VFD26F M P 3LP PART NUMBERS 10 R3623 PILOT ASSEMBLY 11 21590 PILOT BRACKET 14 R9022 BURNER TUBE 16 P182 ORIFICE 19 23493 TUBING ASSEMBLY 21 R3625 VALVE 23 23496 TUBING ASSEMBLY 30...

Page 27: ...e 27 PARTS VIEW 5 PIECE LOG Y ASSEMBL MILLIVOLT VALVE Y ASSEMBL THERMOSTATIC VALVE Y ASSEMBL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 19 20 20 21 21 22 23 23 24 25 26 27 28 29 29 30 31 18 32 33...

Page 28: ...ireplace The magnets on the bottom of speed control will sufficiently hold the speed control in place 13 Attach fan control bracket to upper right side of firebox with one 10 x 1 2 hex screw provided...

Page 29: ...r Kit 110 VOLT AC JUNCTION BOX WHITE SPEED CONTROL FAN SWITCH GROUND BLACK FAN WHITE BLACK SWITCH BRACKET FBBX Wiring Diagram FBBX BLOWER KIT EXTENSION INSTALLATION INSTRUCTIONS cont FBB4 OPTIONAL VAR...

Page 30: ...e 1 side panel into firebox 5 Align clearance hole on brick panel bracket with screw hole in the left or right interior top of firebox Use two 2 10 x 1 2 screws to attach brick panel bracket to interi...

Page 31: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Page 32: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: