CAUTION
All wiring should be done by a qualified electrician and shall
be in compliance with all local, city and state building codes.
before making the electrical connection, make sure that main
power supply is disconnected. The appliance, when installed,
must be electrically grounded in accordance with local codes
or, in the absence of local codes, with the national electrical
code ansi/nfpa 70 (latest edition)
A factory installed junction box is located on the lower right hand side
of the firebox. Wiring must be fed to the junction box and attached
to the receptacle that is provided. Remove the knockout in the
installed junction box to accept wiring into the junction box. Install
a UL listed cable clamp (not supplied) in the knockout hole. Leave
approximately 6 inches of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (neutral) screw.
Install the receptacle into the junction box. Attach cover plate.
Keep the control compartment, logs and burner area surrounding
the logs clean by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer
to lighting instructions located on the log set.
Never obstruct the flow of the combustion and ventilation air. Keep
the front of the firebox clear of all obstacles and materials.
Screens must be closed during operation.
JUNCTION bOx WIRING INSTALLATION INSTRUCTIONS
MAINTENANCE
Figure 20