background image

Page 1

INSTALLATION INSTRUCTIONS

AND OWNER'S MANUAL

DIRECT VENT GAS

FIREpLACE INSERT

TRADITIONAL

DXT(30,35)IN91(N,P)-1

UL FILE NO. Mh 30033

GAS-FIRED

EMPIRE

EMPIRE

Comfort Systems

This appliance may be installed in an aftermarket, 

permanently located, manufactured home (USA only) 

or mobile home, where not prohibited by state or local 

codes.
This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases, unless a certified 

kit is used.

 

WARNING

If not installed, operated and maintained in accordance 

with the manufacturer’s instructions, this product 

could expose you to substances in fuel or from fuel 

combustion which can cause death or serious illness.

Fireplace Insert

Installer: 

Leave this manual with the appliance.

Consumer:  Retain this manual for future reference.

WARNING: If the information in these instructions 

are  not  followed  exactly,  a  fire  or  explosion  may 

result causing property damage, personal injury or 

loss of life.

—  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

—  WhAT TO DO IF YOU SMELL GAS

 

•  Do not try to light any appliance.

 

•  Do  not  touch  any  electrical  switch;  do  not 

use any phone in your building.

 

•  Immediately  call  your  gas  supplier  from  a 

neighbor’s phone. Follow the gas supplier’s 

instructions.

 

•  If you cannot reach your gas supplier, call the 

fire department.

—  Installation and service must be performed by a 

qualified installer, service agency or the gas sup

-

plier.

Summary of Contents for TRADITIONAL DXT30IN NAT

Page 1: ...or from fuel combustion which can cause death or serious illness Fireplace Insert Installer Leave this manual with the appliance Consumer Retain this manual for future reference WARNING If the informa...

Page 2: ...Description Quantity Supplied 1 Latch Tool 1 2 Product Registration Card 1 3 Label Plate 1 4 Warning Label 1 5 1 4 20 Bolt 1 6 Leveling Leg 4 7 AA Battery 2 8 AAA Battery 4 9 Rock Wool 1 See pages 42...

Page 3: ...BLY PLACEMENT 16 FIBER LINER PLACEMENT 17 REFLECTIVE LINER PLACEMENT 18 19 LOG IDENTIFICATION 20 LOG PLACEMENT 21 28 SAFETY SCREEN BARRIER SURROUND AND DECORATIVE FRONT INSTALLATION 29 LIGHTING INSTRU...

Page 4: ...nd draperies The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance Work should be done by a qualified service person Keep burner and control...

Page 5: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Page 6: ...with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code or CSA B149 1 in Canada Available from theAmerican National Standards Institute Inc 11 West 42nd St New Yo...

Page 7: ...and Black DXT30IN DF30VBL Veranda Black DXT30IN DF30VHP Veranda Hammered Pewter DXT30IN DF30VSS Veranda Stainless Steel DXT30IN DF30YBL Lafayette Black DXT30IN DF30YHP Lafayette Hammered Pewter DXT30...

Page 8: ...irements Proper opening size of fireplace required for installation of the fireplace insert INSERT DIMENSIONS in inches DIMENSION DXT30IN DXT35IN A 20 1 8 24 1 16 B 29 3 8 33 3 8 C 18 5 8 21 3 4 D 15...

Page 9: ...C B G H I J CEILING 76 Distance from Face of Fireplace dimensions in inches Height Above Top of Insert dimensions in inches A 10 F 14 B 8 G 17 1 2 C 6 H 21 1 2 D 3 I 24 1 4 E 1 2 J 27 The minimum dis...

Page 10: ...ize or location is not adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied pet...

Page 11: ...e the exposed grille area should be left open NOTICE Surround panel kits have been tested and approved to cover existing air circulation vents or grilles NOTICE Cutting of sheet metal parts of a firep...

Page 12: ...o a zero clearance factory built wood burning fireplace the use of the DVKI Round Vertical Termination Kit should allow you to mount the vent adaptor and cap to the exposed round chimney pipe easily C...

Page 13: ...31210 1 0713 Page 13 VENTING AND INSTALLATION Figure 9...

Page 14: ...ets forming in the flex venting and subsequently dripping out at joints or seams Condensate can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs or having ex...

Page 15: ...assembly 5 Repeat steps 1 through 3 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of the clip while pulling injury may occur Ensure that the latch tool...

Page 16: ...up until it engages to the glass assembly 5 Repeat steps 2 through 4 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of the clip while pulling injury ma...

Page 17: ...ight liner with a retainer bracket by screwing the bracket to the ceiling of the Insert with one 10 x 1 2 screw Figure 19 3 Slide the left liner into the firebox Secure the left liner with a retainer...

Page 18: ...igure 21 Set the burner cover aside If a reflective burner cover is to be used discard the burner cover that has been removed Figure 21 Figure 22 2 Place rear liner in back of unit Figure 23 3 Place t...

Page 19: ...e ceiling of the Insert with one 10 x 1 2 screw Figure 26 5 Slide the left liner into the firebox Secure the left liner with a retainer bracket by screwing the bracket to the ceiling of the Insert wit...

Page 20: ...Log DXT30 Part No 31212 DXT35 Part No 31219 C Right Log DXT30 Part No 31214 DXT35 Part No 31221 D Log Chunk DXT30 Part No 32008 DXT35 Part No 32009 E Front Left Log DXT30 Part No 31215 DXT35 Part No 3...

Page 21: ...own One bag of embers is included with the original purchase of the appliance Use only half of the bag approximately 0 4 oz for ember placement and save the rest for use after maintenance Notice Burne...

Page 22: ...31210 1 0713 Page 22 LOG PLACEMENT 1 Place Rear Log A onto burner pins 1 and 2 See Figure 28 for burner pin identification TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Page 23: ...1 0713 Page 23 LOG PLACEMENT 2 Place Left Log B onto the two left pins on A log and angled down to sit outside the grate NOTICE Log should not touch grate tang TOP VIEW DXT30 Shown FRONT VIEW DXT30 S...

Page 24: ...ace Right Log C onto the two right pins on A log and angled down to sit outside the grate and onto burner pin 4 See Figure 28 for burner pin identification NOTICE Log should not touch grate tang TOP V...

Page 25: ...31210 1 0713 Page 25 LOG PLACEMENT 4 Place Log Chunk D onto burner pins 3 and 5 See Figure 28 for burner pin identification TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Page 26: ...31210 1 0713 Page 26 LOG PLACEMENT 5 Place Right Center Log F onto the two pins on C log and burner pin 6 See Figure 28 for burner pin identification TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Page 27: ...31210 1 0713 Page 27 LOG PLACEMENT 6 Place Left Center Log E onto the two pins on B log and burner pin 7 See Figure 28 for burner pin identification TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Page 28: ...31210 1 0713 Page 28 LOG PLACEMENT 7 Place Front Log G onto the center pin on A log and against the back of the center grate tang TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Page 29: ...the hooks on the fireplace screen over the four pegs two each side on the firebox See Figure 30 2 Secure the screen safety barrier to the firebox with two 10 x 1 2 screws See Figure 30 Figure 30 Insta...

Page 30: ...e is controlled by a hand held remote control Refer to remote instructions for detailed operation information Lighting Instructions A This appliance has a pilot which must be lighted by hand When ligh...

Page 31: ...ed mobile home where not prohibited by local codes This appliance is not convertible for use with other gases unless a certified kit is used CAUTION Do not operate the appliance with glass panel remov...

Page 32: ...rature Ratings 0 50 C 32 122 F Radio Frequency 315 MHz NOTICE THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE RECEIVER IN OR NEAR METAL SEVERELY REDUCES THE SIGNAL RANGE NOTICE TU...

Page 33: ...on Display With the system in the OFF position press the THERMOSTAT key and the MODE key at the same time Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of t...

Page 34: ...sing the DOWN ARROW key once will reduce the flame height by one step until the flame is turned OFF The UP ARROW key will increase the flame height each time it is pressed If the UP ARROW key is press...

Page 35: ...displayed on the LCD screen of the Transmitter Figure 40 SMART Thermostat Operation The Smart Thermostat function adjusts the flame height in accor dance with the difference between the set point temp...

Page 36: ...off or adjust fan speed See Figures 32a and 44 A single beep will confirm reception of the command Figure 43 Fan Icon Figure 44 Fan Speed Control Activated Continuous Pilot Intermittent Pilot CPI IPI...

Page 37: ...the Insert Without a Remote Control Remove the decorative front and outer surround page 29 to ac cess the module With the ON OFF rocker switch in the ON posi tion press with SW1 button on the module...

Page 38: ...ment on a vacuum cleaner to gently remove dust or soot deposits from logs and burner Glass Cleaning It will be necessary to clean the glass periodically During start up condensation which is normal fo...

Page 39: ...n access to the rear of the appliance 5 Remove the two screws securing the bottom flange to the firebox See Figure 49 6 Hand bend the flange so that lays flat See Figure 49 7 Remove blower from applia...

Page 40: ...e the air box and set aside See Figure 53 Figure 53 16 Remove the 18 screws securing the blower access panel to the firebox and set aside Remove the blower access panel and set aside See Figure 54 Fig...

Page 41: ...31210 1 0713 Page 41 DECORATIVE FRONTS...

Page 42: ...11 R10423 R10423 PILOT ASSEMBLY NAT 11 R10424 R10424 PILOT ASSEMBLY LPG 12 28917 28917 PILOT SHIELD 13 31195 31196 GLASS FRAME ASSEMBLY 14 28943 28943 AIR BOX 15 28848 28848 BLOWER ACCESS PANEL 16 31...

Page 43: ...31210 1 0713 Page 43 20 19 21 22 23 24 7 6 8 11 4 3 2 1 13 18 17 16 15 12 14 9 10 5 25 EXPLODED VIEW...

Page 44: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Page 45: ...Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be...

Page 46: ...31210 1 0713 Page 46 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 47: ...31210 1 0713 Page 47 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 48: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...