SAFETY INFORMATION FOR USERS OF LP-GAS

LP-Gas (Propane) is a flammable gas which can cause fires 

and explosions. In its natural state, propane is odorless and 

colorless. You may not know all the following safety precautions 

which can protect both you and your family from an accident. 

Read them carefully now, then review them point by point with the 

 

members of your household. Someday, there may not be a 

minute to lose, everyone’s safety will depend on knowing ex

-

actly what to do. If, after reading the following information, you 

feel you still need more information, please contact your gas 

supplier.

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.

That’s your signal to go into immediate action!

•  Do not operate electric switches, light matches, use your 

phone. Do not do anything that could ignite the gas.

•  Get everyone out of the building, vehicle, trailer, or area. 

Do that IMMEDIATELY.

•  Close all gas tank or cylinder supply valves.

•  LP-Gas is heavier than air and may settle in low areas 

such as basements. When you have reason to suspect 

a gas leak, keep out of basements and other low areas. 

Stay out until firefighters declare them to be safe.

•  Use  your  neighbor’s  phone  and  call  a  trained  LP-Gas 

 

service  person  and  the  fire  department.  Even  though 

you  may  not  continue  to  smell  gas,  do  not  turn  on  the 

gas  again.  Do  not  re-enter  the  building,  vehicle,  trailer, 

or area.

•  Finally, let the service man and firefighters check for es

-

caped gas. Have them air out the area before you return. 

Properly trained LP-Gas service people should repair the 

leak, then check and relight the gas appliance for you.

NO ODOR DETECTED - ODOR FADE

Some people cannot smell well. Some people cannot smell 

the odor of the chemical put into the gas. You must find out if 

you can smell the odorant in propane. Smoking can decrease 

your ability to smell. Being around an odor for a time can affect 

your sensitivity or ability to detect that odor. Sometimes other 

odors in the area mask the gas odor. People may not smell 

the gas odor or their minds are on something else. Thinking 

about smelling a gas odor can make it easier to smell.
The  odorant  in  LP-Gas  is  colorless,  and  it  can  fade  under 

some circumstances. For example, if there is an underground 

leak, the movement of the gas through soil can filter the odor

-

ant. Odorants in LP-Gas also are subject to oxidation. This 

fading can occur if there is rust inside the storage tank or in 

iron gas pipes.

The  odorant  in  escaped  gas  can  adsorb  or  absorb  onto  or 

into walls, masonry and other materials and fabrics in a room. 

That will take some of the odorant out of the gas, reducing its 

odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity 

could vary at different levels. Since it is heavier than air, there 

 

may be more odor at lower levels. Always be sensitive to the 

slightest gas odor. If you detect any odor, treat it as a serious leak. 

 

Immediately go into action as instructed earlier.

SOME POINTS TO REMEMBER

•  Learn to recognize the odor of LP-Gas. Your local LP-Gas 

Dealer can give you a “Scratch and Sniff” pamphlet. Use 

it to find out what the propane odor smells like. If you sus

-

pect that your LP-Gas has a weak or abnormal odor, call 

your LP-Gas Dealer.

•  If you are not qualified, do not light pilot lights, perform 

 

service, or make adjustments to appliances on the LP-

Gas system. If you are qualified, consciously think about 

the odor of LP-Gas prior to and while lighting pilot lights 

or performing service or making adjustments.

•  Sometimes a basement or a closed-up house has a musty 

smell that can cover up the LP-Gas odor. Do not try to 

light pilot lights, perform service, or make adjustments in 

an area where the conditions are such that you may not 

detect the odor if there has been a leak of LP-Gas.

•  Odor fade, due to oxidation by rust or adsorption on walls 

of new cylinders and tanks, is possible. Therefore, people 

should be particularly alert and careful when new tanks or 

cylinders are placed in service. Odor fade can occur in new 

tanks, or reinstalled old tanks, if they are filled and allowed 

to set too long before refilling. Cylinders and tanks which 

have been out of service for a time may develop internal 

rust  which  will  cause  odor  fade.  If  such  conditions  are 

 

suspected  to  exist,  a  periodic  sniff  test  of  the  gas  is 

 

advisable. If you have any question about the gas odor, 

call your LP-Gas dealer. A periodic sniff test of the LP-

Gas is a good safety measure under any condition.

•  If, at any time, you do not smell the LP-Gas odorant and 

you think you should, assume you have a leak. Then take 

the same immediate action recommended above for the 

 

occasion when you do detect the odorized LP-Gas.

•  If  you  experience  a  complete  “gas  out,”  (the  container 

 

is  under  no  vapor  pressure),  turn  the  tank  valve  off 

 

immediately. If the container valve is left on, the container 

may draw in some air through openings such as pilot light 

orifices.  If  this  occurs,  some  new  internal  rusting  could 

 

occur. If the valve is left open, then treat the container as 

a new tank. Always be sure your container is under vapor 

pressure by turning it off at the container before it goes 

 

completely  empty  or  having  it  refilled  before  it  is 

 

completely empty.

Summary of Contents for Mantis BF28 Series

Page 1: ...e Toddlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or...

Page 2: ...es 8 Replace the Remote Receiver Batteries 8 9 Remote Setup Programming the Remote 9 Remote Setup Setting the Temperature Units 9 Starting the Fireplace Remote 9 Remote Operation Manual Mode 9 Remote...

Page 3: ...tall an adjustable safety gate to keep away toddlers young children and other at risk individuals out of the room and away from hot surfaces Clothing or other flammable material should not be placed o...

Page 4: ...d gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a c...

Page 5: ...o operate the fireplace manually set the switch on the remote receiver to the ON position RECEIVER LOCATION ADJ LEARN REMOTE ON OFF 2 Verify there is electrical power to the unit Verify the main burne...

Page 6: ...the first burn er is lit the second igniter will start to glow red the burner light will turn off and the burner will light Once the burner is lit the light will illuminate steadily 5 The Blower will...

Page 7: ...luminated and the burner switch remains in the ON position The rear burner will cycle with the remote To deactivate the Economy Mode press and release the red but ton The button will no longer be illu...

Page 8: ...REMOTE ON BATTERY COMPARTMENT FREQUENCY ADJUSTMENT ACCESS HOLE Remote Setup Install Replace Batteries Both the handheld remote control and the remote receiver located inside of the fireplace are batte...

Page 9: ...If you are unsuccessful in matching the security code on the first attempt wait 1 2 minutes before trying again Remote Setup Setting the Temperature Units To change the temperature units press the ON...

Page 10: ...ar ies 2 F 1 C from the SET temperature Remote Function Lock Out This remote control includes a LOCK OUT feature that allows you to LOCK OUT operation of the fireplace from the TRANS MITTER To activat...

Page 11: ...the glass door if the gasket is missing or damaged Over time the glass door will need to be cleaned For best results it is recommended to clean the glass with high quality fireplace glass cleaner If t...

Page 12: ...the lower louvered panel by lifting up then pulling out For fireplaces equipped with the FHK louverless surround remove the surround by lifting up then pulling out Second release the two door latches...

Page 13: ...e FHK louverless surround the filter is located on the inside bottom flange of the surround FHK Surrounds To clean the filter on fireplaces equipped with the lower louver panel remove the panel and di...

Page 14: ...e Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appl...

Page 15: ...30067 0 0512 Page 15 APPLIANCE MAINTENANCE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 16: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Page 17: ...t tre effectu s par un installateur qualifi une agence de service ou par le fournisseur de gaz AVERTISSEMENT Si vous ne suivez pas exactement ces instructions un incendie ou une explosion peut se prod...

Page 18: ...nsdansdesmaisonspr fabriqu es tats Unis seulement ou des maisons mobiles ou r sidentielles qui peuvent tre utilis es avec le gaz naturel ou le gaz de p trole liqu fi lorsque les dispositions n cessair...

Page 19: ...ux de fer pour le gaz La substance odorante dans le gaz chapp peut tre absorb e ou absorb e sur ou dans les murs la ma onnerie et d autres mat riaux et de tissus dans une chambre Cela enl vera une qua...

Page 20: ...i re en position ON et r glez la t l commande thermostat sur la temp rature souhait e ou mettez la t l commande sur ON Les voyants des br leurs avant et arri re doivent tre allum s avec le voyant du b...

Page 21: ...us voulez changer le br leur arri re allumez premi rement le br leur arri re en appuyant sur l interrupteur la position MARCHE attendez une seconde ensuite allumez le br leur avant en appuyant sur l i...

Page 22: ...r d sactiver en mode conomique appuyez et rel chez le bouton rouge Si cela est souhaitable les interrupteurs des br leurs peuvent tre teints ARR T ou le thermostat contr lera la chaleur INTERRUPTEUR D...

Page 23: ...de combustion Tenez soigneusement le ch ssis du verre et tirez la porte vitr e vers vous N endommagez pas ou n enlevez pas le joint d tanch it de la porte Comment nettoyer la porte vitr e mod les de d...

Page 24: ...e de l entretien normal du radiateur Comment changer les piles de la t l commande Faites glisser le couvercle pour ouvrir le compartiment des piles au dos de la t l commande COMPARTIMENT DES PILES Com...

Page 25: ...ux d entretien devraient tre effectu s par un technicien qualifi ENTRETIEN RECOMMAND ARTICLE D ENTRETIEN FR QUENCE D ENTRETIEN MENSUEL V RIFIER PAR LE PROPRI TAIRE OCCUPANT ANNUEL V RIFIER PAR UN TECH...

Page 26: ...30067 0 0512 Page 10 MAINTENANCE HISTORIQUE DE L APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectu notes...

Page 27: ...30067 0 0512 Page 11 MAINTENANCE HISTORIQUE DE L APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectu notes...

Page 28: ...918 Freeburg Ave Belleville IL 62220 Si vous avez une question g n rale sur nos produits veuillez nous faire parvenir un courriel info empirecomfort com Si vous avez une question sur l entretien ou s...

Reviews: