background image

29432-1-0512

Page 1

—  Do not store or use gasoline or other flammable 

 

vapors and liquids in the vicinity of this or any other  

appliance.

—  WHAT TO DO IF YOU SMELL GAS

 

•  Do not try to light any appliance.

 

•  Do  not  touch  any  electrical  switch;  do  not 

use any phone in your building.

 

•  Immediately  call  your  gas  supplier  from  a 

 

neighbor’s phone. Follow the gas supplier’s 

 

instructions.

 

•  If you cannot reach your gas supplier, call the 

fire department.

—  Installation and service must be performed by a 

 

qualified installer, service agency or the gas sup

-

plier.

EMPIRE

EMPIRE

Comfort Systems

WARNING

HOT GLASS

DO NOT TOUCH

NEVER

WILL

CAUSE BURNS.

GLASS

UNTIL COOLED.

ALLOW CHILDREN

TO TOUCH GLASS.

OWNER’S MANUAL

POWER-VENT 

HIGH-EFFICIENCY FIREPLACE

FG28BM(K)(N,P)-1

IG28BM(N,P)-1

Young children should be carefully supervised when 

they are in the same room as the appliance. Toddlers, 

young  children  and  others  may  be  susceptible  to 

 

accidental  contact  burns.  A  physical  barrier  is 

 

recommended if there are at risk individuals in the 

house.  To  restrict  access  to  a  fireplace  or  stove, 

 

install  an  adjustable  safety  gate  to  keep  toddlers, 

young  children  and  other  at  risk  individuals  out  of 

the room and away from hot surfaces.

This  appliance  may  be  installed  in  an  aftermarket, 

permanently located, manufactured home (USA only) 

or mobile home, where not prohibited by state or local 

codes.

This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases, unless a certified 

kit is used.

WARNING: If not installed, operated and maintained 

in accordance with the manufacturer’s instructions, 

this product could expose you to substances in fuel 

or from fuel combustion which can cause death or 

serious illness.

Installer: 

Leave this manual with the appliance.

Consumer:  Retain this manual for future reference.

WARNING: If the information in these instructions 

are not followed exactly, a fire or explosion may result 

 

causing property damage, personal injury or loss 

of life.

Summary of Contents for FG28BM Series

Page 1: ...to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddler...

Page 2: ...e 9 Starting the Fireplace Display Panel 10 Fireplace Operation Sequence 10 11 Turning the Fireplace Off Remote 12 Turning the Fireplace Off Display Panel 12 Circulating Air Blower Operation 13 Humidi...

Page 3: ...tall an adjustable safety gate to keep away toddlers young children and other at risk individuals out of the room and away from hot surfaces Clothing or other flammable material should not be placed o...

Page 4: ...d gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a c...

Page 5: ...ll flash slowly and the display panel will show a double dash RED LED GREEN LED YELLOW LED If the control board LED s do not activate verify the fireplace is plugged in and the breaker is on Mantis BL...

Page 6: ...ave the value 3 Repeat the process for the minutes and the day 4 If the remote has the batteries installed but the time and date need to be adjusted turn off the remote by holding down the power butto...

Page 7: ...control board LED s will begin to flash alternately RED LED GREEN LED YELLOW LED 4 Each light will flash four times then the fireplace will enter standby mode While in standby mode the green LED will...

Page 8: ...s turned on as when following a power outage or at initial setup the fireplace will activate in Remote Mode by default Remote Operation Manual Mode 1 Turn the remote on by pressing the remote s power...

Page 9: ...the re mote Place the remote control in a good position to monitor the room s average temperature Attention Avoid placing the remote too close to the fireplace as this will affect the remote s temper...

Page 10: ...E LEVEL MANUAL FLAME LEVEL ADJUSTMENT UP MODE SELECT DOWN SET DISPLAY BACK LIGHT Note The start up sequence takes approximately 1 minute 15 seconds to complete 2 Use the UP and DOWN buttons on the rig...

Page 11: ...lt codes and their meanings 6 After the burner lights the flame icon on the display panel will appear and the fireplace will automatically adjust to the flame level shown on the display Mantis BLOWER...

Page 12: ...evious operating mode and turn the fireplace back on Holding down the power button until the backlight turns off will also turn off the remote and the fireplace Note The time date and room temperature...

Page 13: ...Blower Speed After the fireplace is turned off the blower will continue to operate automatically adjusting its speed as the fireplace cools Once the fireplace cools sufficiently the blower will turn o...

Page 14: ...enu To deactivate the Timer Mode return to the Sleep Timer menu and set the timer to 0 zero minutes Press the menu button twice to exit the menu and save the settings The remote s home screen will no...

Page 15: ...timer menu and assume the last settings entered in the menu To deactivate the Program Mode return to the program selection menu and set the program to OFF Press the menu button to exit the menu and s...

Page 16: ...LIGHT Once the display has turned off reset the Mode to the desired form of operation If problems persist or resetting does not work contact a qualified service technician Cleaning the Glass Door WAR...

Page 17: ...by a qualified service person Porcelain Liners Over time a film may form on the porcelain liners It is recommend ed to clean the liners with a high quality fireplace glass cleaner To clean the liners...

Page 18: ...the glass X X Clean the heat exchanger X TROUBLESHOOTING LCD CODES NORMAL OPERATION OPERATION LCD DIGITS CONTROL BOARD LED SEQUENCE Power on sequence Blank Yellow LED permanently OFF Green and red LED...

Page 19: ...ified service person Red LED permanently ON Green LED performs 2 blinks followed by a 1s pause Pressure switch fault A4 Yellow LED permanently OFF Check air pressure switch and air pressure transducer...

Page 20: ...d operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready...

Page 21: ...ersonnes risque dans la maison Pour restreindre l acc s un foyer ou un po le poser un portillon de s curit ajustable de mani re garder les tout petits les jeunes enfants et autres personnes risque hor...

Page 22: ...que 9 D marrer le foyer Panneau d affichage 10 S quence de fonctionnement du foyer 10 11 Fermer le foyer distance 12 Fermer le foyer Panneau d affichage 12 Fonctionnement de la soufflante 13 Fonctionn...

Page 23: ...curit ajustable de mani re garder les tout petits les jeunes enfants et autres personnes risque hors de la pi ce et l cart des surfaces chaudes Ne pas placer de v tements ou autres mati res inflammab...

Page 24: ...dorisant pr sent dans le gaz chapp peut tre adsorb sur ou dans les murs la ma onnerie et autres mat riaux ou tissus dans la pi ce Ceci retire une partie de l odorisant du gaz r duisant l intensit de s...

Page 25: ...ode attente le DEL vert clignotera lentement et le panneau d affichage affichera un double tiret Si les DEL du circuit de commande ne s activent pas s assurer que le foyer est branch et que le disjonc...

Page 26: ...oc dure pour r gler les minutes puis le jour 4 Si la commande distance a d j des piles mais que l heure et le jour doivent tre ajust s fermer la commande distance en tenant le bouton d alimentation en...

Page 27: ...icit est pr sente les voyants DEL rouge et vert du circuit de commande commenceront clignoter en alternance 4 Chaque voyant clignotera quatre fois puis le foyer entrera en mode attente Tandis qu en mo...

Page 28: ...e de courant ou une configuration initiale le foyer sera activ en mode Distance par d faut Op ration distance Mode manuel 1 Ouvrir la commande distance en appuyant le bouton d alimentation sur la comm...

Page 29: ...bon endroit pour surveiller la temp rature moyenne de la pi ce Attention viter de placer la commande distance trop pr s du foyer puisque cela affectera la sonde de temp rature de la commande distance...

Page 30: ...D REMOTE MANUAL OFF FLAME LEVEL MANUAL FLAME LEVEL ADJUSTMENT UP MODE SELECT DOWN SET DISPLAY BACK LIGHT Remarque La s quence de d marrage prend environ 1 minute 15 secondes compl ter 2 Utiliser les b...

Page 31: ...e 19 pour les codes de d faillance et leurs significations 6 Une fois le br leur allum l ic ne flamme sera affich sur le panneau d affichage et le foyer ajustera automatiquement la flamme au niveau de...

Page 32: ...nt pr c dent et allumera le foyer Tenir le bouton d alimentation enfonc jusqu ce que le r tro clairage s teigne fermera aussi la commande distance et le foyer Remarque L heure la date et la temp ratur...

Page 33: ...IGHT Haute vitesse de soufflante Une fois le foyer arr t la soufflante continuera de fonctionner en ajustant automatiquement sa vitesse au fur et mesure que le foyer refroidit Une fois que le foyer es...

Page 34: ...sactiver le mode Minuterie revenir au menu Minuterie Sommeil et r gler la minuterie 0 z ro minutes Appuyer deux fois sur le bouton menu pour quitter le menu et sauvegarder les r glages L cran d accue...

Page 35: ...is s pendant sept secondes lors du r glage de la minuterie sommeil la commande distance sortira automatiquement du menu minuterie sommeil et reviendra aux derniers r glages entr s dans le menu Pour d...

Page 36: ...ECT DOWN DISPLAY BACK LIGHT Une fois l affichage ferm remettre le mode au mode de fonctionnement d sir Si le probl me persiste ou si la r initialisation ne fonctionne pas contacter un technicien d ent...

Page 37: ...technicien d entretien qualifi Rev tements de foyer Avec le temps un film peut se former sur les rev tements de porcelaine Il est recommand de nettoyer les rev tements avec un nettoyant de haute qual...

Page 38: ...l changeur thermique X D PANNAGE CODES ACL FONCTIONNEMENT NORMAL FONCTIONNEMENT CHIFFRES ACL S QUENCE DEL CIRCUIT DE COMMANDE S quence de mise sous tension Blanc DEL jaune TEINT en permanence DEL ver...

Page 39: ...d entretien qualifi DEL rouge ALLUM en permanence DEL vert clignote 2 fois suivi d une pause de 1 s D faillance du manostat A4 DEL jaune TEINT en permanence V rifier le contacteur de pression d air et...

Page 40: ...onformit avec les instructions fournies avec l appareil Conserver une facture un ch que oblit r ou un justificatif de paiement pour attester de la date d achat et tablir la p riode de garantie Acc s f...

Reviews: