31451-2-1013
Page 44
LOG PLACEMENT (4 LOG SET)
Before you begin: This fireplace is supplied with a set of four
ceramic fiber logs. Do not handle these logs with your bare hands.
Always wear gloves to prevent skin irritation from ceramic fibers.
After handling logs, wash your hands gently with soap and water
to remove any traces of fiber.
The positioning of logs is critical to safe and clean operation of this
fireplace. Sooting and other problems may result if the logs are not
properly and firmly positioned in the fireplace. Please refer to
Figure
65, Figure 66, and Figure 67
and corresponding WARNING
,
when
completing the following log placement steps.
1. Remove Decorative Doors (where applicable) by opening and
lifting straight up.
2. Remove Decorative Front.
3. Release two glass frame spring clamps at bottom of firebox
4. Place rear (#1) log onto two pins on rear log support.
5. Place left, front (#2) log onto two left, front pins on burner pan.
6. Place right, front (#3) log onto two right, front pins on burner
pan.
7. Place Branch (#4) onto one pin on rear log and one pin on front
left log.
8. Place decorative rock in front of grates and sides of main burner.
9. After all logs are properly positioned, place small “dime” size
pieces of Rockwool lightly across the front round “blueflame”
ports. Place the ember material (Rockwool pieces) side by side.
Do not stack more than one layer of embers across the burner
ports.
See Figure 65.
ATTENTION: Do not place decorative rock on logs or on
burner. The decorative rock should only be placed on the
fireplace floor.
10. Replace glass door onto firebox.
11. Secure the two glass frame spring clamps at bottom of firebox.
12. Replace Decorative Front.
13. Replace Decorative Doors (where applicable) by aligning hinges
over posts.
Figure 65
Figure 66
WARNING
Failure to position the parts in accordance with this
diagram or failure to use only parts specifically approved
with this appliance may result in property damage or
personal injury.
Figure 67
Log Set Parts List
Index No.
Part No.
Description
1
R10349
Rear Log
2
R10350
Front Left Log
3
R10351
Front Right Log
4
R10352
Top Branch
WARNING
If flame lifts off burner and goes out, verify insulation and
retainer were removed. See page 22.
Summary of Contents for DVP36DP31 Series
Page 21: ...31451 2 1013 Page 21 Figure 30 Figure 31 Figure 32 EXAMPLES TOP VENT RUN...
Page 37: ...31451 2 1013 Page 37 Figure 57 DVVK 4FV DIRECT VENT TERMINATION KIT...
Page 47: ...31451 2 1013 Page 47 Figure 70 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Page 59: ...31451 2 1013 Page 59 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...